CoChat

Recent advances in the management of dry age-related macular degeneration: A review

Open access
Bandello, Francesco, Sacconi, Riccardo, Querques, Lea, Corbelli, Eleonora, Cicinelli, Maria Vittoria, Querques, Giuseppe · 2017 · F1000Research
Cited by 67

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Age-related macular degeneration (AMD), the most important cause of vision loss in elderly people, is a degenerative disorder of the central retina with a multifactorial etiopathology. AMD is classified in dry AMD (d-AMD) or neovascular AMD depending on the presence of choroidal neovascularization. Currently, no therapy is approved for geographic atrophy, the late form of d-AMD, because no treatment can restore the damage of retinal pigment epithelium (RPE) or photoreceptors. For this reason, all treatment approaches in d-AMD are only likely to prevent and slow down the progression of existing atrophy. This review focuses on the management of d-AMD and especially on current data about potential targets for therapies evaluated in clinical trials. Numerous examinations are available in clinics to monitor morphological changes in the retina, RPE and choroid of d-AMD patients. Fundus autofluorescence and optical coherence tomography (OCT) are considered the most useful tools in the diagnosis and follow-up of d-AMD alterations, including the monitoring of atrophy area progression. Instead, OCT-angiography is a novel imaging tool that may add further information in patients affected by d-AMD. Several pathways, including oxidative stress, deposits of lipofuscin, chronic inflammation and choroidal blood flow insufficiency, seem to play an important role in the pathogenesis of d-AMD and represent possible targets for new therapies. A great number of treatments for d-AMD are under investigation with promising results in preliminary studies. However, only few of these drugs will enter the market, offering a therapeutic chance to patients affected by the dry form of AMD and help them to preserve a good visual acuity. Further studies with a long-term follow-up would be important to test the real safety and efficacy of drugs under investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.12688/f1000research.10664.1

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 67

Metadata

Authors
Bandello, F., Sacconi, R., Querques, L., Corbelli, E., Cicinelli, M. V., & Querques, G.
Venue
F1000Research
Published
2017-03-09
Volume
6
Pages
245
ISSN
2046-1402 (ISSN-L)
OpenAlex
W2594015133
Cited by
67
References
14
FWCI
9.77
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recent advances in the management of dry age-related macular degeneration: A review. https://app.cochat.ai/papers/10.12688/f1000research.10664.1
The paper
Bandello, F., Sacconi, R., Querques, L., Corbelli, E., Cicinelli, M. V., & Querques, G. (2017). Recent advances in the management of dry age-related macular degeneration: A review. F1000Research. https://doi.org/10.12688/f1000research.10664.1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.