Cognitive behavioral intervention improves quality of life and perceived illness acceptance in patients after cardiac electrotherapy devices implantation
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Aim. This study is an attempt to provide an analysis of the influence of implementation of cognitive behavioral intervention (CBI) in patients after cardiovascular implantable electronic device (CIED) implantation on the quality of life following the procedure as well as the level of illness acceptance. Method. The study group consisted of patients who underwent standard medical care related to CIED implantation and who additionally received CBI. Patients who received only standard medical care related to CIED implantation constituted a control group. CBI consisted of four sessions conducted over 30 (±3) days after the implantation. Demographic, clinical and psychological factors were assessed. The Acceptance of Illness Scale (AIS) and EuroQol-5D (EQ-5D) were applied. Results. In total, 128 patients (women: 36.7%, mean age 64.5 ± 8.9) were included in the study. The proposed cycle of four structured CBI meetings was well accepted by the patients, which is confirmed by their high turnout for these meetings. After six months, quality of life indices were significantly improved in cardiac electrotherapy recipients assigned to CBI, including: Visual Analogue Scale EQ-5D (80.2 ± 11.8 vs. 64.9 ± 14.3; p < 0.0001) and better acceptance of illness (AIS: 35.6 ± 4.3 vs. 28.7 ± 6.1; p < 0.0001). Conclusions. Implementation of CBI in patients after CIED implantation significantly improved indices of quality of life as well as illness acceptance, when compared to the control group of patients in standard care following electrotherapy. CBI showed multiple benefits in this population, as well as ensures the fulfilment of its expected therapeutic effect, while short duration of the intervention did not prolong the hospitalization itself. © 2019 Polish Psychiatric Association. All rights reserved.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
The Measurement and Valuation of Health Status Using EQ-5D: A European Perspective
(2003) · Springer eBooks · doi:10.1007/978-94-017-0233-1 · Cited by 638 · cited 1×
“The questionnaire is supplemented by the Visual Analogue Scale (VAS) on which the subject presents graphically an assessment of their health condition using the scale from 0 (the worst imaginable health condition) to 100 (the best possible health condition) [11].”
MethodGulliksson, M., Burell, G., Vessby, B., Lundin, L., Toss, H., & Svärdsudd, K. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.510 · Cited by 349
Duru, F., Büchi, S., Klaghofer, R., Mattmann, H., Sensky, T., Buddeberg, C., & Candinas, R. (2001) · Heart · doi:10.1136/heart.85.4.375 · Cited by 128
Psychopathology in Patients with ICDs over Time: Results of a Prospective Study
KAPA, S., ROTONDI-TREVISAN, D., MARIANO, Z., AVES, T., IRVINE, J., DORIAN, P., & HAYES, D. L. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02599.x · Cited by 112 · cited 1×
“We impose many restrictions on patients and inform them on and warn against numerous threats [19].”
Pacemaker implantation and quality of life in the Mode Selection Trial (MOST)
Fleischmann, K. E., Orav, E. J., Lamas, G. A., Mangione, C. M., SCHRON, E. B., Lee, K. L., & Goldman, L. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.02.1031 · Cited by 109 · cited 1×
“The results presented in this study generally correspond to those obtained in majority of others, including the MOST and CTOPP studies [15, 16].”
ResultEckert, M., & Jones, T. (2002) · International Journal of Nursing Practice · doi:10.1046/j.1440-172x.2002.00357.x · Cited by 94 · cited 1×
“, of developing anxiety or depressive disorders, post-traumatic stress disorder or poor quality of life [5, 6].”
BackgroundEffect of pacing mode on health-related quality of life in the Canadian Trial of Physiologic Pacing
Newman, D. M., Lau, C., TANG, A. S. L., Irvine, J., Paquette, M., Woodend, K., Dorian, P., Gent, M., Kerr, C. R., & Connolly, S. J. (2003) · American Heart Journal · doi:10.1067/mhj.2003.167 · Cited by 93 · cited 1×
“The results presented in this study generally correspond to those obtained in majority of others, including the MOST and CTOPP studies [15, 16].”
ResultPrevention of implantable defibrillator shocks by cognitive behavioral therapy: A pilot trial
Chevalier, P., Cottraux, J., Mollard, E., Sai, N., Brun, S., Burri, H., Restier, L., & Adeleine, P. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.10.007 · Cited by 81
Leosdottir, M., Sigurdsson, E., Reimarsdottir, G., Gottskalksson, G., Torfason, B., Vigfusdottir, M., Eggertsson, S., & Arnar, D. O. (2006) · EP Europace · doi:10.1093/europace/euj052 · Cited by 56 · cited 1×
“Studies show that when it comes to a general evaluation, implantation of a device improves healthrelated quality of life, however, as many as approximately 35% of patients with PCM or ICD showed symptoms of general psychological distress [2, 3].”
BackgroundDoering, L. V., McGuire, A., Eastwood, J., Chen, B. C., Bodán, R. C., Czer, L. S. C., & Irwin, M. R. (2015) · European Journal of Cardiovascular Nursing · doi:10.1177/1474515115592292 · Cited by 44
Carroll, D. L., Hamilton, G. A., & Kenney, B. J. (2002) · European Journal of Cardiovascular Nursing · doi:10.1016/s1474-5151(02)00040-3 · Cited by 25
Individualised quality of life after pacing. Does mode matter?
Gribbin, G. M., Kenny, R. A., MCCUE, P., Toff, W. D., Bexton, R. S., & McComb, J. M. (2004) · EP Europace · doi:10.1016/j.eupc.2004.07.011 · Cited by 23
Hirsh, A. T., Sears, S. F., & CONTI, J. B. (2009) · Journal of Clinical Psychology in Medical Settings · doi:10.1007/s10880-009-9160-0 · Cited by 22
Irvine, J., Stanley, J., Ong, L., Cribbie, R., Ritvo, P., Katz, J., Dorian, P., O’Donnell, S., Harris, L., Cameron, D., et al. (2010) · Journal of Cognitive Psychotherapy · doi:10.1891/0889-8391.24.4.246 · Cited by 14 · cited 1×
“Some patients have serious difficulties when trying to accept cardiac electrotherapy device and adapt to the situation: they think that implantation was not necessary, they do not accept the device, have a negative attitude towards medical check-ups, do not follow doctor’s recommendations, do not accept restrictions,…”
BackgroundPsychokardiologie: Wie Herz und Psyche zusammenhängen
Bunz, M., Kindermann, I., Karbach, J., Wedegärtner, S. M., Böhm, M., & Lenski, D. (2015) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/s-0040-100440 · Cited by 9
Cited by
Ski, C. F., Taylor, R. S., McGuigan, K., Long, L., Lambert, J. D., Richards, S. H., & Thompson, D. R. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013508.pub3 · Cited by 128
The Impact of Cardiac Devices on Patients’ Quality of Life—A Systematic Review and Meta-Analysis
Willy, K., Ellermann, C., Reinke, F., Rath, B., Wolfes, J., Eckardt, L., Doldi, F., Wegner, F. K., Köbe, J., & Morina, N. (2022) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd9080257 · Cited by 38
Fedorowicz, O., Jazwinska-Tarnawska, E. K., Adamiszak, A., Niewiński, P., Krajewska, M., & Wiela−Hojeńska, A. (2021) · Journal of Pharmacy & Pharmaceutical Sciences · doi:10.18433/jpps31592 · Cited by 6
“6), in patients with critical lower limb ischemia after the surgery (score 32) (12,17).”
BackgroundXiaoning, L. U., ZHANG, H., Tixin, G. U., et al. (2021) · Minerva Surgery · doi:10.23736/s2724-5691.21.09205-4 · Cited by 2
Sikora, K., Wawryniuk, A., Łuczyk, R. J., et al. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192114133 · Cited by 1
Metadata
- Authors
- Sobczak-Kaleta, M., Qawoq, H., Krawczyk, M., Wierzbowska-Drabik, K., & Kasprzak, J.
- Affiliations
- Medical University of Lodz (PL)
- Venue
- Psychiatria Polska
- Published
- 2019-10-30
- Volume
- 53
- Issue
- 5
- Pages
- 1037-1051
- ISSN
- 0033-2674 (ISSN-L)
- 2391-5854
- OpenAlex
- W2990315048
- Semantic Scholar
- e89c5fa8b8dfa8a37a17c2ffad462702a8dabdfb
- Cited by
- 6
- References
- 15
- Citations by year
- 2024: 2 · 2022: 2 · 2021: 2
- FWCI
- 0.72
- Type
- journal article
- Language
- pl
- Open access
- diamond
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor)
- creativecommons.org/licenses/by/4.0/ (am)
- creativecommons.org/licenses/by/4.0/ (tdm)
- Locations
- Psychiatria Polska (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Social Sciences › Psychology › Clinical Psychology › Mindfulness and Compassion Interventions
- Keywords
- cognitive-behavioral intervention, cardiac implantable electronic devices, quality of life, acceptance of illness, cardiac pacing, cardiac resynchronization therapy, Acceptance of Illness Scale, EQ-5D
- MeSH terms
- Adaptation, Psychological, Adult, Aged, Anxiety, Arrhythmias, Cardiac, Cardiac Pacing, Artificial, Depression, Female, Humans, Male, Middle Aged, Pacemaker, Artificial, Quality of Life, Surveys and Questionnaires, Self Concept, Severity of Illness Index, Cognitive Behavioral Therapy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A second model labelled each claim on 2026-10-26 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.