Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The receiver operating characteristic (ROC) curve

Open access
Yang, Shengping, Berdine, Gilbert · 2017 · The Southwest Respiratory and Critical Care Chronicles

Abstract

Results from routine blood tests can be used potentially as biomarkers for identifying disease.An example would be using the hemoglobin concentration to identify patients with iron deficiency anemia.We want a binary (Yes/No) answer, but the values of these predictive tests are continuous; I am wondering how to use them to facilitate a diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.12746/swrccc.v5i19.391

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 250

Metadata

Authors
Yang, S., & Berdine, G.
Venue
The Southwest Respiratory and Critical Care Chronicles
Published
2017-05-05
Volume
5
Issue
19
Pages
34
ISSN
2325-9205 (ISSN-L)
OpenAlex
W2611864304
Cited by
250
References
2
FWCI
3.20
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The receiver operating characteristic (ROC) curve. https://app.cochat.ai/papers/10.12746/swrccc.v5i19.391
The paper
Yang, S., & Berdine, G. (2017). The receiver operating characteristic (ROC) curve. The Southwest Respiratory and Critical Care Chronicles. https://doi.org/10.12746/swrccc.v5i19.391

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.