Rhinomanometry 1988: Practice and trends
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This report discusses characteristics and measurement of transnasal pressures and flow of respiratory air, indices of nasal airway patency, and components of contemporary rhinomanometric systems. Sources of error that can result from mucovascular fluctuation and from the use of face masks and nasal nozzles are delineated. Useful adjuncts to rhinomanometry include microcomputation and plethysmography. State‐of‐the‐art transducers and microcircuitry add reliability and economy. Aerodynamic parameters closely correlated with chronic obstructive nasal symptoms have yet to be determined. Nevertheless, resistance calculated from concomitant measurements of transnasal pressure and flow, as recommended by the International Committee on Standardization of Rhinomanometry, provides a practical index of nasal patency and aids the exchange of rhinological information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Partitioning of respiratory flow resistance in man
Ferris, B. G., Mead, J., & Opie, L. H. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.4.653 · Cited by 448
The site and function of the nasal valve
Haight, J. S. J., & Cole, P. (1983) · The Laryngoscope · doi:10.1288/00005537-198301000-00009 · Cited by 372
Self-citation
Cited by
Constantian, M. B., & Clardy, B. R. (1996) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199607000-00007 · Cited by 283
Nasal obstruction as a risk factor for sleep apnoea syndrome
Lofaso, F., Coste, A., d′ortho, M. P., Zerah-Lancner, F., Delclaux, C., Goldenberg, F., & Harf, A. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16d12.x · Cited by 247
(2004) · PubMed Central · Cited by 220
Surgery of the turbinates and “empty nose” syndrome
Scheithauer, M. O. (2010) · German Medical Science GMS Publishing House · doi:10.3205/cto000067 · Cited by 121
Nasal airway dilation and obstructed breathing in sleep
Metes, A., Cole, P., Hoffstein, V., & Miljeteig, H. (1992) · The Laryngoscope · doi:10.1288/00005537-199209000-00017 · Cited by 58
Self-citation
Metadata
- Authors
- Cole, P.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 1989-03
- Volume
- 99
- Issue
- 3
- Pages
- 311-315
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W1964668847
- Cited by
- 60
- References
- 2
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rhinomanometry 1988: Practice and trends. https://app.cochat.ai/papers/10.1288/00005537-198903000-00014
- The paper
- Cole, P. (1989). Rhinomanometry 1988: Practice and trends. The Laryngoscope. https://doi.org/10.1288/00005537-198903000-00014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.