Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Informing Selection of Nanomaterial Concentrations for ToxCast in Vitro Testing Based on Occupational Exposure Potential

Open access
Gangwal, Sumit, Brown, James S., Wang, Amy, Houck, Keith A., Dix, David J., Kavlock, Robert J., Hubal, Elaine A. Cohen·2011·Environmental Health Perspectives

Abstract

BACKGROUND: Little justification is generally provided for selection of in vitro assay testing concentrations for engineered nanomaterials (ENMs). Selection of concentration levels for hazard evaluation based on real-world exposure scenarios is desirable. OBJECTIVES: Our goal was to use estimates of lung deposition after occupational exposure to nanomaterials to recommend in vitro testing concentrations for the U.S. Environmental Protection Agency's ToxCast™ program. Here, we provide testing concentrations for carbon nanotubes (CNTs) and titanium dioxide (TiO2) and silver (Ag) nanoparticles (NPs). METHODS: We reviewed published ENM concentrations measured in air in manufacturing and R&D (research and development) laboratories to identify input levels for estimating ENM mass retained in the human lung using the multiple-path particle dosimetry (MPPD) model. Model input parameters were individually varied to estimate alveolar mass retained for different particle sizes (5-1,000 nm), aerosol concentrations (0.1 and 1 mg/m3), aspect ratios (2, 4, 10, and 167), and exposure durations (24 hr and a working lifetime). The calculated lung surface concentrations were then converted to in vitro solution concentrations. RESULTS: Modeled alveolar mass retained after 24 hr is most affected by activity level and aerosol concentration. Alveolar retention for Ag and TiO2 NPs and CNTs for a working-lifetime (45 years) exposure duration is similar to high-end concentrations (~ 30-400 μg/mL) typical of in vitro testing reported in the literature. CONCLUSIONS: Analyses performed are generally applicable for providing ENM testing concentrations for in vitro hazard screening studies, although further research is needed to improve the approach. Understanding the relationship between potential real-world exposures and in vitro test concentrations will facilitate interpretation of toxicological results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1289/ehp.1103750

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 163

Metadata

Authors
Gangwal, S., Brown, J. S., Wang, A., Houck, K. A., Dix, D. J., Kavlock, R. J., & Hubal, E. A. C.
Venue
Environmental Health Perspectives
Published
2011-11
Volume
119
Issue
11
Pages
1539-1546
ISSN
  • 0091-6765 (ISSN-L)
  • 1552-9924
OpenAlex
W2086242851
Cited by
163
References
3
FWCI
6.04
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Informing Selection of Nanomaterial Concentrations for ToxCast in Vitro Testing Based on Occupational Exposure Potential. https://app.cochat.ai/papers/10.1289/ehp.1103750
The paper
Gangwal, S., Brown, J. S., Wang, A., Houck, K. A., Dix, D. J., Kavlock, R. J., & Hubal, E. A. C. (2011). Informing Selection of Nanomaterial Concentrations for ToxCast in Vitro Testing Based on Occupational Exposure Potential. Environmental Health Perspectives. https://doi.org/10.1289/ehp.1103750

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.