CoChat

Reproducibility of Nocturnal Blood Pressure Assessed by Self-Measurement of Blood Pressure at Home

HOSOHATA, Keiko, KIKUYA, Masahiro, OHKUBO, Takayoshi, METOKI, Hirohito, ASAYAMA, Kei, INOUE, Ryusuke, OBARA, Taku, HASHIMOTO, Junichiro, TOTSUNE, Kazuhito, HOSHI, Haruhisa, SATOH, Hiroshi, IMAI, Yutaka · 2007 · Hypertension Research
Cited by 50

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

To assess the reproducibility of nocturnal blood pressure (BP) during sleep as measured using a self-measurement device at home, we obtained repeated nocturnal home BP at 0200 h and quality of sleep assessment from a diary in 556 subjects (71% women, 62.4+/-11.1 years) in the general population. We used an Omron device (HEM-747IC-N, Omron Healthcare Co., Ltd., Kyoto, Japan), with which the time and frequency of monitoring can be preset and the readings stored. The mean+/-SD of the difference between test-retest BP measurements was 0.7+/-15.1 mmHg systolic and 0.2+/-9.7 mmHg diastolic with a mean interval of 5.9 days. The absolute differences were greater than 10 mmHg in 261 (46.9%) subjects for systolic and 145 (26.0%) subjects for diastolic. There was no evidence of regression to the mean in nocturnal measurements over at least three nights (n=390, p>0.22). The differences (the first minus the second measurement) were large in subjects who experienced sleep disturbance only in the first (n=64, 2.3+/-13.6 mmHg and 1.6+/-9.6 mmHg for systolic and diastolic, respectively) or second sessions (n=56, -4.1+/-16.4 mmHg and -2.5+/-11.4 mmHg) compared with the subjects without sleep disturbance (n=66, 1.5+/-17.8 mmHg and 0.8+/-10.3 mmHg) and those with sleep disturbance (n=370, 0.9+/-14.5 mmHg and 0.2+/-9.3 mmHg) in both sessions. In conclusion, the reproducibility of single nocturnal BP as assessed using a self-measurement device at home was not good, especially for subjects who experienced different quality of sleep in each session. To evaluate nocturnal BP using a self-measurement device, estimation of quality of sleep is indispensable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1291/hypres.30.707

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 50

Metadata

Authors
HOSOHATA, K., KIKUYA, M., OHKUBO, T., METOKI, H., ASAYAMA, K., INOUE, R., OBARA, T., HASHIMOTO, J., TOTSUNE, K., HOSHI, H., SATOH, H., & IMAI, Y.
Venue
Hypertension Research
Published
2007
Volume
30
Issue
8
Pages
707-712
ISSN
  • 0916-9636 (ISSN-L)
  • 1348-4214
OpenAlex
W2047353135
Cited by
50
References
4
FWCI
1.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.