CoChat

Patients' Self-Reported Adherence to Cardiovascular Medication Using Electronic Monitors as Comparators

Open access
Zeller, Andreas, Ramseier, Esther, Teagtmeyer, Anne, Battegay, Edouard · 2008 · Hypertension Research
Cited by 95

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The aim of this study was to evaluate self-reporting of adherence to cardiovascular medication using electronic pillboxes (medical event monitoring system [MEMS]) as the gold standard comparator. In total, 78 individuals (52% hypertensives, 21% diabetics, 27% with dyslipidemia) were recruited prospectively from an outpatient clinic setting in Switzerland. Participants completed two self-report measures (visual analogue scale [VAS] and a validated self-reporting questionnaire) at baseline and were asked to use MEMS as their pillbox for the subsequent 10 weeks. Patients expressed their medication adherence behaviour on a VAS (0 mm="I never take any tablets"; 100 mm="I take all tablets as prescribed") and entered one of six numbers (from 1: perfect adherence to 6: non-adherence) on the questionnaire. Medication compliance was monitored for 75 d on average. Mean (+/-SD, range) scores for MEMS with respect to timing adherence, correct dosing, and self-administration adherence were 79+/-25% (8-100%), 83+/-20% (24-100%), and 92+/-17% (54-118%), respectively. A majority of participants (78.8%) over-reported their adherence to the VAS (93+/-7 mm, 73-100), and VAS scores correlated poorly with MEMS recordings (Spearman's rho for timing adherence, correct dosing, self-administration adherence 0.29 [p=0.018], 0.24 [p=0.051], 0.26 [p=0.036], respectively). Similarly, we found no correlation between adherence as expressed in the questionnaire and MEMS (regression coefficients <0.1). We conclude that a majority of patients over-report adherence to cardiovascular medication if asked to complete a visual analogue scale and a validated questionnaire. Therefore, using self-reporting as the sole means of assessing medication compliance is insufficiently accurate to detect poor adherence. (Hypertens Res 2008; 31: 2037-2043).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1291/hypres.31.2037

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 95

Metadata

Authors
Zeller, A., Ramseier, E., Teagtmeyer, A., & Battegay, E.
Venue
Hypertension Research
Published
2008-11
Volume
31
Issue
11
Pages
2037-2043
ISSN
  • 0916-9636 (ISSN-L)
  • 1348-4214
OpenAlex
W2078203204
Cited by
95
References
2
FWCI
2.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.