Aims: This article describes a study aiming to establish the concurrent validity and test-retest reliability of the Biometrics E-LINK EP9 electronic dynamometer. Methods: Grip strength testing was performed on 49 healthy participants. Three trials were completed for the right and left hands on the Biometrics and Jamar dynamometers, using a repeated measures design. Data was compared and used to establish concurrent validity of the Biometrics dynamometer. Fifteen participants repeated the testing a week later, for test-retest reliability of the Biometrics dynamometer. Findings: The Biometrics E-LINK EP9 evaluation system was found to have excellent validity (ICC 0.983-0.986). However, a small but statistically significant difference between the right hand grip strength scores of the Biometrics (31.65 ± 8.89) and Jamar (30.44 ± 9.49) dynamometer was revealed (p ≤ 0.05). Test-retest reliability of the Biometrics system proved excellent, with ICC scores of 0.986 for the left hand and 0.996 for the right hand. Conclusions: The results indicate that the Biometrics E-LINK EP9 evaluation system is valid, reliable and comparable to the Jamar hydraulic dynamometer, when used for measuring grip strength with the second handle position. However, due to the statistically significant differences found for the right hand grip strength scores, therapists should exercise caution when interchanging instruments.

Integrity signals

Registry

Crossref · 10.12968/ijtr.2011.18.5.258

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The physical and cognitive status of each participant was tested using the 5x sit-to-stand-test (5XSST), grip force test, and Montreal Cognitive Assessment (MoCA).

    “In addition, the physical and cognitive status of each participant was tested.A functional test for the general fitness and frailty (5x sit-to-stand-test (5XSST), (Treacy and Hassett 2018)), the grip force test (Allen and Barnett 2011) and a test to measure the cognitive status of the participants (Montreal Cognitive Assessment (MoCA), (Nasreddine et al. 2005)) were examined.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Allen, D., & Barnett, F.
Affiliations
James Cook University (AU)
Venue
International Journal of Therapy and Rehabilitation
Published
2011-05
Volume
18
Issue
5
Pages
258-264
ISSN
  • 1741-1645 (ISSN-L)
  • 1759-779X
OpenAlex
W1999347017
Cited by
50
References
15
Citations by year
2026: 4 · 2025: 11 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 6 · 2018: 2 · 2017: 4 · 2016: 2 · 2015: 1 · 2014: 1 · 2013: 2
FWCI
1.03
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Therapy and Rehabilitation (publishedVersion)
  • ResearchOnline - JCU (James Cook University) (submittedVersion)
Topics
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
  • Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Medical Practices and Rehabilitation
Keywords
grip strength, Jamar dynamometer, concurrent validity, test-retest reliability, inter-instrument agreement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review