The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns
Abstract
A series of tests on concrete-filled SHS (Square Hollow Section) stub columns (twenty), columns (eight) and beam-columns (twenty one) were carried out. The main parameters varied in the tests are (1) Confinement factor ( ${\xi}$ ) from 1.08 to 5.64, (2) concrete compression strength from 10.7MPa to 36.6MPa, (3) tube width to thickness ratio from 20.5 to 36.5. (4) load eccentricity (e) from 15 mm to 80 mm and (5) column slenderness ( ${\lambda}$ ) from 45 to 75. A mechanics model is developed in this paper for concrete-filled SHS stub columns, columns and beam-columns. A unified theory is described where a confinement factor ( ${\xi}$ ) is introduced to describe the composite action between the steel tube and filled concrete. The predicted load versus axial strain relationship is in good agreement with stub column test results. Simplified models are derived for section capacities and modulus in different stages of the composite sections. The predicted beam-column strength is compared with that of 331 beam-column tests with a wide range of parameters. A good agreement is obtained. The predicted load versus midspan deflection relationship for beam-columns is in good agreement with test results. A simplified model is developed for calculating the member capacity of concrete-filled SHS columns. Comparisons are made with predicted columns strengths using the existing codes such as LRFD (AISC 1994), AIJ (1997), and EC4 (1996). Simplified interaction curves are derived for concrete-filled beam-columns.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The constrained concrete constitutive model proposed by Linhai [45] is commonly used, and the hoop coefficient ξ governs the interaction between the steel tube and core concrete.
“The constrained concrete constitutive model proposed by Linhai [45] is commonly used, and the hoop coefficient ξ governs the interaction between the steel tube and core concrete.”
From Bond-Slip Performances of Ultra-High Performance Concrete Steel Tube Columns Made of a Large-Diameter Steel Tube with Internally Welded Steel Bars (2023) · cites this paper as [45]
Citations
Cites
Theoretical Stress‐Strain Model for Confined Concrete
Mander, J. B., Priestley, M. J. N., & Park, R. (1988) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1988)114:8(1804 · Cited by 8,623
Observed Stress‐Strain Behavior of Confined Concrete
Mander, J. B., Priestley, M. J. N., & Park, R. (1988) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1988)114:8(1827 · Cited by 874
Axially Loaded Concrete-Filled Steel Tubes
Schneider, S. P. (1998) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1998)124:10(1125 · Cited by 816
Local and post-local buckling of concrete filled steel welded box columns
Uy, B. (1998) · Journal of Constructional Steel Research · doi:10.1016/s0143-974x(98)80102-8 · Cited by 252
State of the Art of Concrete-Filled Steel Tubular Columns
Shams, M., & Saadeghvaziri, M. A. (1997) · ACI Structural Journal · doi:10.14359/505 · Cited by 170
Ultimate strength and ductility of state-of-the-art concrete-filled steel bridge piers in Japan
Kitada, T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00026-6 · Cited by 149
Cyclic Tests of Concrete-Filled Steel Box Columns
Ge, H., & Usami, T. (1996) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1996)122:10(1169 · Cited by 141
Cyclic Load Behavior of Concrete‐Filled Tubular Braces
Liu, Z., & Goel, S. C. (1988) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1988)114:7(1488 · Cited by 61
Void-Filled SHS Beams Subjected to Large Deformation Cyclic Bending
Zhao, X., & Grzebieta, R. H. (1999) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1999)125:9(1020 · Cited by 50
Self-citationFire Resistance of Concrete Filled Steel Tubular Columns
Han, L. (1998) · Advances in Structural Engineering · doi:10.1177/136943329800200105 · Cited by 25
Self-citation
Flagged first, then by citations
Research works printed but not linked: 13
- 1969, High-Strength Concrete, SP121, 195
- 1967, J. Struct. Engrg., 93, 113
- 1992, Journal of Structural Engineering, 118, 3006
- 1994, Journal of Constructional Steel Research, 30, 607
- 1969, J. Struct. Engrg., 95, 2565
- 1986, Proceedings, Civil Engineering, 374, 447
- 1994, J. Structural Engineering, 40A, 1401
- 1994, J. Struct. Engrg, 40B, 411
- 1997, ACI Structural Journal, 94, 558
- 1979, Trans. of A.I.J., 275, 55
- 1989, Constructional Structures, 6, 10
- 1993, Journal of Constructional Structures, 8, 28
- 1991, Steel Construction, Australian Institute of Steel Construction, 25, 2
Cited by
Sorted by citations
Han, L.-H., Xu, C.-Y., & Tao, Z. (2019) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2018.02.038 · Cited by 193
Self-citationEffects of debonding on circular CFST stub columns
Xue, J.-Q., Briseghella, B., & Chen, B.-C. (2012) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2011.08.002 · Cited by 156
Deng, N., Zhao, H., Yao, D., & Tang, Z. (2023) · Materials · doi:10.3390/ma16103836 · Cited by 14
“The constrained concrete constitutive model proposed by Linhai [45] is commonly used, and the hoop coefficient ξ governs the interaction between the steel tube and core concrete.”
MethodInfluential
Metadata
- Authors
- Han, L.-H., Zhao, X.-L., & Tao, Z.
- Affiliations
- Fuzhou University (CN)
- Venue
- Steel and Composite Structures
- Publisher
- Techno-Press
- Published
- 2001-03-25
- Volume
- 1
- Issue
- 1
- Pages
- 51-74
- ISSN
- 1229-9367 (ISSN-L)
- OpenAlex
- W2067312258
- Cited by
- 425
- References
- 10
- Citations by year
- 2026: 38 · 2025: 44 · 2024: 40 · 2023: 34 · 2022: 37 · 2021: 42 · 2020: 27 · 2019: 14 · 2018: 18 · 2017: 16 · 2016: 12 · 2015: 9 · 2014: 9 · 2013: 12 · 2012: 8
- FWCI
- 54.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Steel and Composite Structures (publishedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
- Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
- Physical Sciences › Engineering › Mechanical Engineering › Structural Integrity and Reliability Analysis
- Keywords
- concrete-filled steel tubes, square hollow sections, stub columns, beam-columns, confinement factor, composite action, mechanical model, load-strain relationship, elastic modulus, load-deflection behavior, interaction curves, slenderness, eccentric loading, design code comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review