Mitigation of motions of tall buildings with specific examples of recent applications
Abstract
Flexible structures may experience excessive levels of vibration under the action of wind, adversely affecting serviceability and occupant comfort. To ensure the functional performance of a structure, various design modifications are possible, ranging from alternative structural systems to the utilization of passive and active control devices. This paper presents an overview of state-of-the-art measures that reduce the structural response of buildings, including a summary of recent work in aerodynamic tailoring and a discussion of auxiliary damping devices for mitigating the wind-induced motion of structures. In addition, some discussion of the application of such devices to improve structural resistance to seismic events is also presented, concluding with detailed examples of the application of auxiliary damping devices in Australia, Canada, China, Japan, and the United States.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passive Energy Dissipation Systems in Structural Engineering
Dargush, G. F., & Soong, T. T. (1997) · Medical Entomology and Zoology · Cited by 880
Semi-active control systems for seismic protection of structures: a state-of-the-art review
Symans, M. D., & Constantinou, M. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00225-3 · Cited by 706
Controlling buildings: a new frontier in feedback
(1997) · IEEE Control Systems · doi:10.1109/37.642972 · Cited by 445
Damping in structures: its evaluation and treatment of uncertainty
Kareem, A., & Gurley, K. (1996) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(96)00004-9 · Cited by 315
Self-citationPerformance of Multiple Mass Dampers under Random Loading
Kareem, A., & Kline, S. (1995) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1995)121:2(348) · Cited by 306 · cited 1×
“Although TMDs are often effective, even better responses have been noted through the use of multiple-damper configurations (MDCs) which consist of several dampers placed in parallel with distributed natural frequencies around the control tuning frequency (Kareem & Kline 1995).”
BackgroundSelf-citationTuned Liquid Damper (TLD) for Suppressing Horizontal Motion of Structures
Fujino, Y., Sun, L., Pacheco, B. M., & Chaiseri, P. (1992) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1992)118:10(2017 · Cited by 245
On the Stability of the Impact Damper
Masri, S. F., & Caughey, T. K. (1966) · Journal of Applied Mechanics · doi:10.1115/1.3625125 · Cited by 232
Effectiveness of tuned liquid dampers under wind excitation
Tamura, Y., Fujii, K., Ohtsuki, T., Wakahara, T., & Kohsaka, R. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00031-2 · Cited by 224
Self-citationPerformance of tuned mass dampers under wind loads
Kwok, K. C. S., & Samali, B. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00035-6 · Cited by 206
Use of viscoelastic dampers in reducing wind- and earthquake-induced motion of building structures
Samali, B., & Kwok, K. C. S. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00034-5 · Cited by 200
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Nonlinear dissipative devices in structural vibration control: A review
Lu, Z., Wang, Z., Zhou, Y., & Lu, X. (2018) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2018.02.052 · Cited by 501
A state-of-the-art review of structural control systems
Saaed, T. E., Nikolakopoulos, G., Jonasson, J.-E., & Hedlund, H. (2015) · Journal of Vibration and Control · doi:10.1177/1077546313478294 · Cited by 333
Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
Giaralis, A., & Petrini, F. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001863 · Cited by 330
Giaralis, A., & Taflanidis, A. A. (2018) · Structural Control and Health Monitoring · doi:10.1002/stc.2082 · Cited by 328
Large-scale vibration energy harvesting
Zuo, L., & Tang, X. (2013) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x13486707 · Cited by 285
Tuned mass damper inerter for seismic control of multi-story buildings: Ten years since inception
Konar, T., & Ghosh, A. (. (2024) · Structures · doi:10.1016/j.istruc.2024.106459 · Cited by 57
Min, K.-W., Kim, J., & Lee, H.-R. (2014) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2014.03.003 · Cited by 38
Ruiz, R. O., Taflanidis, A. A., & Lopez-Garcia, D. (2016) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.01.014 · Cited by 32
Compliant liquid column damper modified by shape memory alloy device for seismic vibration control
Gur, S., Mishra, S. K., Bhowmick, S., & Chakraborty, S. (2014) · Smart Materials and Structures · doi:10.1088/0964-1726/23/10/105009 · Cited by 30
Calayir, M., Tao, J., Mercan, O., & Bezabeh, M. A. (2026) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.70129 · Cited by 8
State of the Art of Structural Control
(2003) · doi:10.1061/(asce)0733-9445(2003)129:7(845
Metadata
- Authors
- Kareem, A., Kijewski, T., & Tamura, Y.
- Venue
- Wind and Structures
- Publisher
- Techno-Press
- Published
- 1999-09-25
- Volume
- 2
- Issue
- 3
- Pages
- 201-251
- ISSN
- 1226-6116 (ISSN-L)
- OpenAlex
- W2024780366
- Cited by
- 440
- References
- 25
- FWCI
- 20.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.