The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Development of power assisting suit for assisting nurse labor
Open accessAbstract
In order to realize a power assisting suit for assisting a nurse caring a patient in her arm, a hardness sensor of muscle using load cell and a pneumatic rotary actuator utilizing pressure cuffs have been developed. The power assisting suit consists of shoulders, arms, waist and legs made of aluminum, and is fitted on the nurse body. The power assisting suit is originated with the concept of a master and slave system in one body. The arms, waist and legs have the pneumatic rotary actuators. The pneumatic rotary actuators are constructed with pressure cuffs sandwiched between thin plates. The action of the arms, waist and legs of the nurse are sensed with the muscle hardness sensor utilizing load cell with diaphragm mounted on a sensing tip. The dent of the sensing tip corresponds to the hardness of the muscle so that exerting muscle force produces electric signal. This paper gives the design and characteristics of the power assisting suit using the cuff type pneumatic rotary actuators and the muscle hardness sensor verifying its practicability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“a nurse-assisting exoskeleton was developed by the Kanagawa Institute of Technology in Atsugi, Japan to help nurses transfer patients [47]”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [47]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EMG-based Prototype Powered Assistive System for Walking Aid
Okamura, J. (1999) · Medical Entomology and Zoology · Cited by 60
Development of Power Assisting Suit for Assisting Nurse Labor.
YAMAMOTO, K., HYODO, K., Ishii, M., & Matsuo, T. (2001) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.67.1499 · Cited by 36
Self-citationSpecial Issue: Robotics for Aging Society. Review of Transfer System for the Handicapped.
Hashino, S. (1993) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.11.649 · Cited by 20
Koyama, T., YAMAFJUJI, K., & Tanaka, T. (2000) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.66.3679 · Cited by 18
Powered Suit for Assisting Nurse Labor Employing Muscle Sensor and Sliding Rotary Actuator
Yamamoto, K. (1997) · Medical Entomology and Zoology · Cited by 7
Self-citationDevelopment of Powered Suit for Assisting Nurse Labor
Yamamoto, K. (1994) · Medical Entomology and Zoology · Cited by 7
Self-citationPowered Suit for Assisting Nurse Labor-Muscle Sensor and Slide Box Actuator-
Yamamoto, K. (1996) · Medical Entomology and Zoology · Cited by 4
Self-citationPowered Suit for Assisting Nurse Labor-Development of muscle sensor and slide box rotary actuator-
Yamamoto, K. (1996) · Medical Entomology and Zoology · Cited by 2
Self-citationDevelopment of Muscle Sensor of Powered Suit for Assisting Nurse Labor
Yamamoto, K. (1997) · Medical Entomology and Zoology · Cited by 2
Self-citation
Research works printed but not linked: 16
- (2) Okazaki, T., Nagasawa, T. and Takahashi, T., Intellectualization of the Nursing Aid Robot-about an Open Prolog Subsystem-, Proc. 25th Conf. Jpn. Soc. ME&BE, (in Japanese), (1986), p. 443.
- (3) Tejima, N., Development of a Simple Device for Transfer Aid, Proc. Conf. JSPE '98, (in Japanese), (1998), p. 612.
- (5) Kawamura, S., Yonezawa, T., Fujimoto, K., Hayakawa, Y., Isaka, T. and Pandian, S. R., Development of an Active Orthsis for Knee Motion by Using Pneumatic Actuators, Proc. ICMA2000, Osaka, (2000), pp. 615-620.
- (7) Yamamoto, K., Miyanishi, H. and Imai, M., Development of Pneumatic Actuator for Powered Arm, Proc. JHPS Autumn Meeting, (in Japanese), (1991), pp. 85-88.
- (8) Yamamoto, K., Imai, M. and Miyanishi, H., Development of Powered Arm for Assisting Nurse Labor-Pneumatic Actuator, Proc. JSME D&D Conf. '92, (in Japanese), Vol. A (1992), pp. B35-B38.
- (9) Yamamoto, K., Imai, M. and Miyanishi, H., Development of Powered Arm for Assisting Nurse Labor, Proc., 8th National Sympo. Fluid Control, SICE, J., (in Japanese), (1993), pp. 57-62.
- (10) Yamamoto, K. and Hyodo, K., Powered Arm and Leg for Assisting Nurse Labor, Proc. 1st Asian Control Conf., SICE, J., (1994), pp. 561-564.
- (12) Yamamoto, K., Hyodo, K. and Matsuo, T., Development of Powered Suit for Assisting Nurse Labor, Proc. of 10th National Symposium on Fluid Control, SICE, J., (in Japanese), (1995), pp. 131-136.
- (13) Yamamoto, K., Hyodo, K. and Matsuo, T., Powered Suit for Assisting Nurse Labor, Fluid Power (Proc. 3rd International Symposium on Fluid Power), JHPS, (1996), pp. 415-420.
- (18) Yamamoto, K., Hyodo, K., Matsuo, T. and Sawada, K., Development of Muscle Sensor of Power Assisting Suit for Assisting Nurse Labor, Proc. JSME D&D Conf. '98, (in Japanese), (1998), pp. 105-106.
- (19) Yamamoto, K., Hyodo, K., Matsuo, T. and Sawada, K., Development of Pneumatic Actuator of Power Assisting Suit for Assisting Nurse Labor, Proc. JSME D&D Conf. '98, (in Japanese), (1998), pp. 109-110.
- (20) Yamamoto, K., Hyodo, K., Matsuo, T. and Sawada, K., Development of Power Assisting Suit for Assisting Nurse Labor, 13th National Symposium on Fluid Control, SICE, J., (in Japanese), (1998), pp. 73-76.
- (21) Ishii, M., Yamamoto, K. and Hyodo, K., Development of Power Assisting Suit for Assisting Nurse Labor, Proc., 14th National Symposium on Fluid Control, SICE, J., (in Japanese), (1999), pp. 87-90.
- (23) Yamamoto, K., Hyodo, K., Ishii, M. and Matsuo, T., Development of Power Assisting Suit for Assisting Nurse Labor-Sensing System, CD-ROM Proc, of JSME D&D Conf. 2000, (in Japanese), (2000), Paper No. 714.
- (24) Ishii, M., Yamamoto, K., Hyodo, K. and Matsuo, T., Development of Power Assisting Suit for Assisting Nurse Labor-Driving system, CD-ROM Proc, of JSME D&D Conf. 2000, (in Japanese), (2000), Paper No. 715.
- (25) Yamamoto, K., Hyodo, K., Ishii, M. and Matsuo, T., Development and Evaluation of Muscle Hardness Sensor for Power Assisting Suit: Proc. 17th Sensing Forum, SICE, J., (in Japanese), (2000), pp. 163-168.
Cited by
Sorted by citations
Items 101–169 of 169
A robust adaptive neural controller to drive a knee joint actuated orthosis
Mefoued, S., Daachi, M. E. H., Daâchi, B., Mohammed, S., & Amirat, Y. (2012) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2012.6491205 · Cited by 8
Walking assistance apparatus using a spatial parallel link mechanism and a weight bearing lift
Tanaka, E., Ikehara, T., Sato, Y., Yusa, H., Sakurai, T., SAEGUSA, S., Ito, K., & Yuge, L. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975469 · Cited by 8
Robust Repetitive Learning Control of Lower Limb Exoskeleton with Hybrid Electro-hydraulic System
Yang, Y. M., Huang, D., & Dong, X. (2018) · IEEE Data Driven Control and Learning Systems Conference (DDCLS) · doi:10.1109/ddcls.2018.8516005 · Cited by 8
Comparison of Control Techniques in a Weight Lifting Exoskeleton
Rosales-Díaz, I., López-Gutiérrez, R., Suarez, Á., Salazar, S., Osorio-Cordero, A., Sierra, H. A., & Lozano, R. (2019) · Journal of Bionic Engineering · doi:10.1007/s42235-019-0053-0 · Cited by 8
Improvement of a Lightweight Power Assist Suit for Nursing Care
Ishii, C., & Yoshida, K. (2019) · International Journal of Engineering and Technology · doi:10.7763/ijet.2019.v11.1157 · Cited by 8
Exoskeletons for Lower Limb Applications: A Review
Alqahtani, M., Cooper, G., Diver, C., & Bártolo, P. (2020) · Springer eBooks · doi:10.1007/978-3-030-35876-1_8 · Cited by 8
WPAL for Human Power Assist during Walking Using Pseudo-compliance Control
Chen, F., Yu, Y. T., Ge, Y., Sun, J., & Deng, X. (2007) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2007.4303888 · Cited by 8
Investigation of Movements of Lower-Limb Assistive Industrial Device
Jatsun, S. F., Malchikov, A., & Yatsun, A. S. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-26118-4_22 · Cited by 7
A human motion prediction algorithm for Non-binding Lower Extremity Exoskeleton
Wang, M., Wu, X., Liu, D., Wang, C., Zhang, T., & Wang, P. (2015) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2015.7279315 · Cited by 7
Ghobj, S., Akl, A., El-Farr, A., Ayyash, M., & Abu-Khalaf, J. (2017) · International Conference on Research and Education in Mechatronics (REM) · doi:10.1109/rem.2017.8075232 · Cited by 7
A parallel mechanism used on human hip joint power assist
Yu, Y. T., Liang, W., & Ge, Y. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.5420740 · Cited by 7
Dynamic analysis and control strategy of the Wearable Power Assist Leg
Fang, Y., Yu, Y., Chen, F., & Ge, Y. (2008) · IEEE International Conference on Automation and Logistics (ICAL) · doi:10.1109/ical.2008.4636308 · Cited by 7
An Analysis of Human Motion for Control of a Wearable Power Assist System
Kawai, S., Naruse, K., Yokoi, H., & Kakazu, Y. (2004) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2004.p0237 · Cited by 7
Intelligent Assistive Knee Orthotic Device Utilizing Pneumatic Artificial Muscles
Chandrapal, M. (2012) · UC Research Repository (University of Canterbury) · doi:10.26021/1196 · Cited by 7
Yu, Y. T., & Liang, W. (2012) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2012.6225383 · Cited by 6
Style-phase adaptation of human and humanoid biped walking patterns in real systems
Matsubara, T., 宇都, 太., Noda, T., Teramae, T., & Morimoto, J. (2014) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids.2014.7041348 · Cited by 6
A Study on the Effect of Soft Wearable Suit Using Elastic Band
CHA, E.-H., Oh, S. Y., Hong, C. U., Yu, M., & Kwon, T. (2022) · Journal of the Korean Society for Precision Engineering · doi:10.7736/jkspe.021.037 · Cited by 6
That Which Does Not Stabilize, Will Only Make Us Stronger
Kazerooni, H., & Steger, R. (2007) · Springer eBooks · doi:10.1007/978-3-540-48113-3_33 · Cited by 6
SHAPE STABILIZER USING AN ARTICULATION-TYPE PASSIVE ELEMENT
Mitsuda, T., & MATSUO, N. (2005) · Proceedings of the JFPS International Symposium on Fluid Power · doi:10.5739/isfp.2005.722 · Cited by 6
Modeling and control of 4-DOF powered upper limb exoskeleton
Wang, H., Ni, S., & Tian, Y. (2017) · Youth Academic Annual Conference of Chinese Association of Automation (YAC) · doi:10.1109/yac.2017.7967424 · Cited by 6
Wang, W., Liang, X. H., Li, L., Gong, L., Deng, L., Hu, X., Zhang, S., & Sun, S. (2024) · Smart Materials and Structures · doi:10.1088/1361-665x/ad94bb · Cited by 5
User-friendly walking assistance device able to walk on stairs safely
Zhang, Y., Tanaka, E., Lee, H., SAEGUSA, S., & Yuge, L. (2017) · IEEE International Conference on Advanced Intelligent Mechatronics (AIM) · doi:10.1109/aim.2017.8014122 · Cited by 5
Chen, F., Yu, Y. F., Ge, Y., Sun, J. D., & Xiaohong, D. (2007) · doi:10.5772/5092 · Cited by 5
Upper limb rehabilitation support device using a pneumatic cylinder
Kirihara, K., Saga, N., & Saito, N. (2008) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2008.4758207 · Cited by 5
A Survey in the Different Designs and Control Systems of Powered Exoskeleton for Lower Extremities
Baldovino, R. G., & Jamisola, R. S. (2017) · Journal of Mechanical Engineering and Biomechanics · doi:10.24243/jmeb/1.4.192 · Cited by 5
Personal Assistive Devices for Elderlies
D’Angelo, L., Kreutzer, J. F., Neuhaeuser, J., Reimer, S. M. F., & Lueth, T. C. (2014) · Human-computer interaction series · doi:10.1007/978-1-4471-6413-5_8 · Cited by 4
Arm Orthosis/Prosthesis Control Based on Surface EMG Signal Extraction
Suberbiola, A., Zulueta, E., López-Guede, J. M., Etxeberria‐Agiriano, I., & Caesbroeck, B. V. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40846-5_51 · Cited by 4
A controller system design for pneumatic-powered motion assist device using a load observer
Murata, H., Okada, T., YAMAHIRA, S., HARADA, R., & FUJII, F. (2015) · Transactions of the JSME (in Japanese) · doi:10.1299/transjsme.14-00579 · Cited by 4
Research on the Multi-Sensors Perceptual System of A Wearable Power Assist Leg Based on CANBUS
Sun, J. Q., Yu, Y. T., Ge, Y., & Feng, C. (2007) · IEEE International Conference on Information Acquisition · doi:10.1109/icia.2007.4295712 · Cited by 4
Inoue, T., Nomura, S., Takahashi, Y., Kawai, M., & Taniai, Y. (2016) · IEEE Congress on Evolutionary Computation (CEC) · doi:10.1109/cec.2016.7743996 · Cited by 3
Analysis of parallel mechanism for human hip joint power assist
Yu, Y. T., Liang, W., & Ge, Y. (2010) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2010.5555040 · Cited by 3
Design of the force-sensors system of WPAL
Sun, J., Chen, F., Wu, B. Y., Deng, X., Yu, Y. T., & Ge, Y. J. (2007) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2007.4522355 · Cited by 3
Development of Hydrostatic Knee Power Assist Device and Its Control with Sensitivity Maximization
Kaminaga, H., Tanaka, H., Amari, T., Niwa, Y., & Nakamura, Y. (2011) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.29.609 · Cited by 3
Development of leg support system Manipuleg for hemiplegia based on manual control
KONDO, R., SUZUKI, T., MINEGISHI, Y., OKADA, Y., & Matsuda, K.-I. (2016) · Transactions of the JSME (in Japanese) · doi:10.1299/transjsme.16-00088 · Cited by 3
Fujita, T., Kawamoto, H., & Sankai, Y. (2016) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2016.7866468 · Cited by 3
Jitosho, H., & FUJII, F. (2017) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2017.8122758 · Cited by 3
Liu, J., Gan, D., Huang, B., Li, Z., & Kang, Y. (2017) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2017.8273205 · Cited by 3
Human-Robot Interaction System for Micromanipulation Assistance
Kojima, O., Huang, S., Murakami, K., Ishikawa, M., & Yamakawa, Y. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8592819 · Cited by 3
A Real-Time Assistance Control Strategy for Active Knee Exoskeleton
Zhou, S., Zhao, Z., Liu, X., Zhu, X., & Chen, J. (2021) · Lecture notes in electrical engineering · doi:10.1007/978-981-16-6324-6_63 · Cited by 3
Robotic Assistance for Peg-and-Hole Alignment by Mimicking Annular Solar Eclipse Process
Huang, S., Murakami, K., Ishikawa, M., & Yamakawa, Y. (2022) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2022.p0946 · Cited by 2
Design of Upper Limb Assistive Device Using a Pneumatic Cylinder
Saga, N. (2013) · Journal of Rehabilitation Robotics · doi:10.12970/2308-8354.2013.01.01.2 · Cited by 2
FUJII, F., Hirose, Y., Murata, H., & Okada, T. (2014) · IEEE RO-MAN · doi:10.1109/roman.2014.6926405 · Cited by 2
A PAWL for Enhancing Strength and Endurance during Walking Using Interaction Force and
Chen, F., Yu, Y. T., Ge, Y., Sun, J., & Xiao-hong, D. (2007) · Cited by 2
Stability Analysis of a Human Arm Interacting with a Force Augmenting Device
Gadi, S. K., Osorio-Cordero, A., Lozano, R., & Garrido, R. A. (2016) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-016-0420-6 · Cited by 2
Assisting strategy of walking assistive device on inclined terrain
Kim, I., Cho, W., & Yang, H. (2013) · International Conference on Ubiquitous Robots and Ambient Intelligence · doi:10.1109/urai.2013.6677331 · Cited by 2
Design of a Capacitance Sensor for Human Intention Detection of Daily Living Activities
Jung, P.-G., Amirat, Y., & Mohammed, S. (2020) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2020.12.1417 · Cited by 2
A Power Transmission Design for an Untethered Hydraulic Ankle Orthosis
Houle, K. L. (2012) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 2
Classification of waist motion by neural networks — Toward power assist suit for caregiver
Kurita, A., & Nakakuki, T. (2011) · Society of Instrument and Control Engineers of Japan · Cited by 1
Development of a Walking-Assistance Apparatus for Neuro-Rehabilitation
TANAKA, E., Ikehara, T., Sakurai, T., Suzuki, T., Roppongi, S., SAEGUSA, S., & Yuge, L. (2012) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.162.258 · Cited by 1
The Design of Lower Extremity Exoskeleton of Power Assist Robot
Yan, L., Wu, J., Li, Y. B., Liu, J. H., & Yang, F. (2013) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.278-280.618 · Cited by 1
Stability Analysis for a Force Augmenting Device Considering Delays in the Human Model
Gadi, S. K., Garrido, R. A., Lozano, R., & Osorio, A. (2013) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2013-63751 · Cited by 1
Fontana, M., Vertechy, R., Marcheschi, S., Salsedo, F., & Bergamasco, M. (2014) · Cited by 1
Mayoral, R., Logan, S. W., & Fitter, N. T. (2025) · Frontiers in Robotics and AI · doi:10.3389/frobt.2025.1520216 · Cited by 1
Design of the Upper Limb Rehabilitation Support Device Using a Pneumatic Cylinder
Kirihara, K., Saga, N., & Saito, N. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-10817-4_52 · Cited by 1
Gait recognition and trajectory prediction of Lower limb Load Exoskeleton
Yang, Y. M., Zhou, P., Ma, L., Shu, Y., Zhou, J., Yao, J., & Zhang, Q. (2016) · Chinese Control Conference (CCC) · doi:10.1109/chicc.2016.7554340 · Cited by 1
Manipulability Inclusive Principle for Assistive Result Evaluation of Assistive Mechanism
Liang, W., & Yu, Y. T. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/2767129 · Cited by 1
Supporting Effects on Muscles of a Motion Assistive Wear Depending on the Fixture Position
Ogawa, K., Kadowaki, A., Shimatani, K., Hasegawa, M., Takahashi, K., Tsuji, T., Kurita, Y., & PRESTO (Sakigake), J. S. A. T. A. (. 7. G. (2018) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2018.p0729 · Cited by 1
Human Cooperative Control of Lower-limb Robotic Exoskeleton Based on Region Function
Zhao, K., Yuan, Y., & Li, Z. (2019) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2019.8834166 · Cited by 1
Robots and Nursing: Concepts, Relationships and Practice
Campling, A. S., Tanioka, T., & Locsin, R. C. (2007) · doi:10.1007/978-1-137-01881-6_6 · Cited by 1
Active exoskeleton tracking control system design via singular perturbation technique
Yurkevich, V. D. (2015) · International Multi-Conference on Engineering, Computer and Information Sciences (SIBIRCON) · doi:10.1109/sibircon.2015.7361866
DESIGN OF AN UPPER LIMB INDEPENDENCE SUPPORT DEVICE USING A PNEUMATIC CYLINDER
Saga, N., & Kirihara, K. (2011)
Gadi, S. K., Osorio, A., & Lozano, R. (2014) · International Conference on System Theory, Control and Computing (ICSTCC) · doi:10.1109/icstcc.2014.6982382
Human Adaptation Towards a Force Augmenting Device: Experimental Results
Gadi, S. K., Osorio-Cordero, A., Lozano, R., & Garrido, R. A. (2017) · Journal of Applied Science & Process Engineering · doi:10.33736/jaspe.437.2017
Importance of compliant joints in below-knee exoskeletons for improving walking
She, H., Zhao, Y. M., Huang, G., & Zhu, J. (2021) · International Conference on Intelligent Computing and Human-Computer Interaction (ICHCI) · doi:10.1109/ichci54629.2021.00072
Lin, Y., Lin, S.-Y., & Kao, S.-Y. (2025) · Bioengineering · doi:10.3390/bioengineering12060590
Conceptual design of upper and lower extremity exoskeleton
Hamsan, R., Zaidi, J., Anuar, S. A., Zabor, D. A. B., & Annathurai, S. (2026) · AIP conference proceedings · doi:10.1063/5.0308728
Causally-Informed Evaluation of Wearable Assistive Robots in Real-World Caregiving
Fujita, W., Tokunaga, R., Higuchi, A., & Shibata, T. (2026) · IEEE RO-MAN · doi:10.1109/ro-man72286.2026.11714756
Metadata
- Authors
- YAMAMOTO, K., HYODO, K., ISHII, M., & MATSUO, T.
- Affiliations
- Kanagawa Institute of Technology (JP)
- ORCID
- MATSUO, Takashi
- Venue
- JSME International Journal Series C
- Published
- 2002
- Volume
- 45
- Issue
- 3
- Pages
- 703-711
- ISSN
- 1344-7653 (ISSN-L)
- 1347-538X
- OpenAlex
- W2029188366
- Cited by
- 169
- References
- 9
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2022: 6 · 2021: 4 · 2020: 8 · 2019: 13 · 2018: 9 · 2017: 14 · 2016: 12 · 2015: 8 · 2014: 14 · 2013: 9 · 2012: 12
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- JSME International Journal Series C (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- load cell, diaphragm sensor, master-slave architecture, wearable exoskeleton, patient handling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review