The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Development of power assisting suit for assisting nurse labor
Open accessAbstract
In order to realize a power assisting suit for assisting a nurse caring a patient in her arm, a hardness sensor of muscle using load cell and a pneumatic rotary actuator utilizing pressure cuffs have been developed. The power assisting suit consists of shoulders, arms, waist and legs made of aluminum, and is fitted on the nurse body. The power assisting suit is originated with the concept of a master and slave system in one body. The arms, waist and legs have the pneumatic rotary actuators. The pneumatic rotary actuators are constructed with pressure cuffs sandwiched between thin plates. The action of the arms, waist and legs of the nurse are sensed with the muscle hardness sensor utilizing load cell with diaphragm mounted on a sensing tip. The dent of the sensing tip corresponds to the hardness of the muscle so that exerting muscle force produces electric signal. This paper gives the design and characteristics of the power assisting suit using the cuff type pneumatic rotary actuators and the muscle hardness sensor verifying its practicability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“a nurse-assisting exoskeleton was developed by the Kanagawa Institute of Technology in Atsugi, Japan to help nurses transfer patients [47]”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [47]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EMG-based Prototype Powered Assistive System for Walking Aid
Okamura, J. (1999) · Medical Entomology and Zoology · Cited by 60
Development of Power Assisting Suit for Assisting Nurse Labor.
YAMAMOTO, K., HYODO, K., Ishii, M., & Matsuo, T. (2001) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.67.1499 · Cited by 36
Self-citationSpecial Issue: Robotics for Aging Society. Review of Transfer System for the Handicapped.
Hashino, S. (1993) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.11.649 · Cited by 20
Koyama, T., YAMAFJUJI, K., & Tanaka, T. (2000) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.66.3679 · Cited by 18
Powered Suit for Assisting Nurse Labor Employing Muscle Sensor and Sliding Rotary Actuator
Yamamoto, K. (1997) · Medical Entomology and Zoology · Cited by 7
Self-citationDevelopment of Powered Suit for Assisting Nurse Labor
Yamamoto, K. (1994) · Medical Entomology and Zoology · Cited by 7
Self-citationPowered Suit for Assisting Nurse Labor-Muscle Sensor and Slide Box Actuator-
Yamamoto, K. (1996) · Medical Entomology and Zoology · Cited by 4
Self-citationPowered Suit for Assisting Nurse Labor-Development of muscle sensor and slide box rotary actuator-
Yamamoto, K. (1996) · Medical Entomology and Zoology · Cited by 2
Self-citationDevelopment of Muscle Sensor of Powered Suit for Assisting Nurse Labor
Yamamoto, K. (1997) · Medical Entomology and Zoology · Cited by 2
Self-citation
Research works printed but not linked: 16
- (2) Okazaki, T., Nagasawa, T. and Takahashi, T., Intellectualization of the Nursing Aid Robot-about an Open Prolog Subsystem-, Proc. 25th Conf. Jpn. Soc. ME&BE, (in Japanese), (1986), p. 443.
- (3) Tejima, N., Development of a Simple Device for Transfer Aid, Proc. Conf. JSPE '98, (in Japanese), (1998), p. 612.
- (5) Kawamura, S., Yonezawa, T., Fujimoto, K., Hayakawa, Y., Isaka, T. and Pandian, S. R., Development of an Active Orthsis for Knee Motion by Using Pneumatic Actuators, Proc. ICMA2000, Osaka, (2000), pp. 615-620.
- (7) Yamamoto, K., Miyanishi, H. and Imai, M., Development of Pneumatic Actuator for Powered Arm, Proc. JHPS Autumn Meeting, (in Japanese), (1991), pp. 85-88.
- (8) Yamamoto, K., Imai, M. and Miyanishi, H., Development of Powered Arm for Assisting Nurse Labor-Pneumatic Actuator, Proc. JSME D&D Conf. '92, (in Japanese), Vol. A (1992), pp. B35-B38.
- (9) Yamamoto, K., Imai, M. and Miyanishi, H., Development of Powered Arm for Assisting Nurse Labor, Proc., 8th National Sympo. Fluid Control, SICE, J., (in Japanese), (1993), pp. 57-62.
- (10) Yamamoto, K. and Hyodo, K., Powered Arm and Leg for Assisting Nurse Labor, Proc. 1st Asian Control Conf., SICE, J., (1994), pp. 561-564.
- (12) Yamamoto, K., Hyodo, K. and Matsuo, T., Development of Powered Suit for Assisting Nurse Labor, Proc. of 10th National Symposium on Fluid Control, SICE, J., (in Japanese), (1995), pp. 131-136.
- (13) Yamamoto, K., Hyodo, K. and Matsuo, T., Powered Suit for Assisting Nurse Labor, Fluid Power (Proc. 3rd International Symposium on Fluid Power), JHPS, (1996), pp. 415-420.
- (18) Yamamoto, K., Hyodo, K., Matsuo, T. and Sawada, K., Development of Muscle Sensor of Power Assisting Suit for Assisting Nurse Labor, Proc. JSME D&D Conf. '98, (in Japanese), (1998), pp. 105-106.
- (19) Yamamoto, K., Hyodo, K., Matsuo, T. and Sawada, K., Development of Pneumatic Actuator of Power Assisting Suit for Assisting Nurse Labor, Proc. JSME D&D Conf. '98, (in Japanese), (1998), pp. 109-110.
- (20) Yamamoto, K., Hyodo, K., Matsuo, T. and Sawada, K., Development of Power Assisting Suit for Assisting Nurse Labor, 13th National Symposium on Fluid Control, SICE, J., (in Japanese), (1998), pp. 73-76.
- (21) Ishii, M., Yamamoto, K. and Hyodo, K., Development of Power Assisting Suit for Assisting Nurse Labor, Proc., 14th National Symposium on Fluid Control, SICE, J., (in Japanese), (1999), pp. 87-90.
- (23) Yamamoto, K., Hyodo, K., Ishii, M. and Matsuo, T., Development of Power Assisting Suit for Assisting Nurse Labor-Sensing System, CD-ROM Proc, of JSME D&D Conf. 2000, (in Japanese), (2000), Paper No. 714.
- (24) Ishii, M., Yamamoto, K., Hyodo, K. and Matsuo, T., Development of Power Assisting Suit for Assisting Nurse Labor-Driving system, CD-ROM Proc, of JSME D&D Conf. 2000, (in Japanese), (2000), Paper No. 715.
- (25) Yamamoto, K., Hyodo, K., Ishii, M. and Matsuo, T., Development and Evaluation of Muscle Hardness Sensor for Power Assisting Suit: Proc. 17th Sensing Forum, SICE, J., (in Japanese), (2000), pp. 163-168.
Cited by
Sorted by citations
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,336
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 721
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“…[46]; a nurse-assisting exoskeleton was developed by the Kanagawa Institute of Technology in Atsugi, Japan to help nurses transfer patients [47]; a soft lower extremity robotic exosuit was developed by Wehner et al [48] at Harvard University (Cambridge, MA, USA) to augment normal muscle…”
Method
Metadata
- Authors
- YAMAMOTO, K., HYODO, K., ISHII, M., & MATSUO, T.
- Affiliations
- Kanagawa Institute of Technology (JP)
- ORCID
- MATSUO, Takashi
- Venue
- JSME International Journal Series C
- Published
- 2002
- Volume
- 45
- Issue
- 3
- Pages
- 703-711
- ISSN
- 1344-7653 (ISSN-L)
- 1347-538X
- OpenAlex
- W2029188366
- Cited by
- 169
- References
- 9
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 2 · 2022: 6 · 2021: 4 · 2020: 8 · 2019: 13 · 2018: 9 · 2017: 14 · 2016: 12 · 2015: 8 · 2014: 14 · 2013: 9 · 2012: 12
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- JSME International Journal Series C (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- load cell, diaphragm sensor, master-slave architecture, wearable exoskeleton, patient handling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›