The DOI matches its Crossref record.
Cementless acetabular components
Abstract
Four hundred and fifteen patients with cementless acetabular components of either a smooth threaded (130) or porous surfaced (285) variety were compared for clinical symptoms and radiographic signs of component loosening. At a mean 4.8 year follow-up none of the patients with porous acetabular components had signs of component instability. At a mean 3.9 year follow-up 27 (21%) of the patients with a smooth threaded acetabular component showed radiographic signs of instability and 33 (25%) had clinical symptoms. The disappointing short-term results with these threaded cups in our hands have prompted us to abandon their use in favour of the porous surfaced hemispherical cups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schmalzried, T. P., Guttmann, D., Grecula, M., & Amstutz, H. C. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199405000-00008 · Cited by 289
Trindade, M. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00181-2 · Cited by 80
Metadata
- Authors
- Engh, C., Griffin, W., & Marx, C.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1990-01
- Volume
- 72-B
- Issue
- 1
- Pages
- 53-59
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2256478101
- Cited by
- 224
- References
- 0
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cementless acetabular components. https://app.cochat.ai/papers/10.1302/0301-620x.72b1.2298795
- The paper
- Engh, C., Griffin, W., & Marx, C. (1990). Cementless acetabular components. The Journal of Bone and Joint Surgery. British volume. https://doi.org/10.1302/0301-620x.72b1.2298795
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.