The DOI matches its Crossref record.
Immune response to polyglycolic acid implants
Abstract
Cytological analysis of material aspirated from the effusion which occasionally develops around a polyglycolic acid (PGA) osteosynthesis implant showed a predominance of inflammatory monocytes and in particular lymphocytes. In order to discover whether PGA implants are immunologically inert, density gradient-isolated peripheral blood mononuclear cells were cultured in 0.2 ml of 10% delta FCS-RPMI 1640 culture medium supplemented with 10 mg PGA. Phytohaemagglutinin (PHA) lectin, a purified protein derivate of tuberculin (PPD) antigen and culture medium alone were used as positive and negative controls. We studied lymphocyte activation kinetics on days 0, 1, 3 and 5. Major histocompatibility complex locus II antigen (MHC locus II antigen) and interleukin-2 receptor (IL-2R) expression were analysed using the avidin-biotin-peroxidase complex (ABC) method and lymphocyte DNA synthesis by using 3H-thymidine incorporation and beta-scintillation counting. Especially on culture days 0 and 1, lymphocytes and monocytes were seen by light microscopy to be attached to PGA particles. However, our results show no PGA-induced lymphocyte DNA synthesis, but PGA-induced MHC locus II antigen and IL-2R activation marker expression was seen, greater than in negative controls, but less than that seen in PPD antigen driven lymphocyte response. This suggests that PGA is an immunologically inert implant material, but it does seem to induce inflammatory mononuclear cell migration and adhesion, leading to a slight non-specific lymphocyte activation. This activation is lower than that seen in mitogen and antigen-driven lymphocyte responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Shirtliff, M. E., & Mader, J. T. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.4.527-544.2002 · Cited by 652
Osteoinduction of bone grafting materials for bone repair and regeneration
García-Gareta, E., Coathup, M. J., & Blunn, G. W. (2015) · Bone · doi:10.1016/j.bone.2015.07.007 · Cited by 649
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
Böstman, O., & Pihlajamäki, H. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00129-0 · Cited by 509
Adverse Tissue Reactions to Bioabsorbable Fixation Devices
B??stman, O. M., & Pihlajam??ki, H. K. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00026 · Cited by 476
Metadata
- Authors
- Santavirta, S., Konttinen, Y., Saito, T., Gronblad, M., Partio, E., Kemppinen, P., & Rokkanen, P.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1990-07
- Volume
- 72-B
- Issue
- 4
- Pages
- 597-600
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2187042068
- Cited by
- 160
- References
- 0
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immune response to polyglycolic acid implants. https://app.cochat.ai/papers/10.1302/0301-620x.72b4.2166048
- The paper
- Santavirta, S., Konttinen, Y., Saito, T., Gronblad, M., Partio, E., Kemppinen, P., & Rokkanen, P. (1990). Immune response to polyglycolic acid implants. The Journal of Bone and Joint Surgery. British volume. https://doi.org/10.1302/0301-620x.72b4.2166048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.