COMPARTMENT MONITORING IN TIBIAL FRACTURES: THE PRESSURE THRESHOLD FOR DECOMPRESSION
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We made a prospective study of 116 patients with tibial diaphyseal fractures who had continuous monitoring of anterior compartment pressure for 24 hours. Three patients had acute compartment syndrome (2.6%). In the first 12 hours of monitoring, 53 patients had absolute pressures over 30 mmHg and 30 had pressures over 40 mmHg, with four higher than 50 mmHg. Only one patient had a differential pressure (diastolic minus compartment pressure) of less than 30 mmHg; he had a fasciotomy. In the second 12-hour period 28 patients had absolute pressures over 30 mmHg and seven over 40 mmHg. Only two had differential pressures of less than 30 mmHg; they had fasciotomies. None of our 116 patients had any sequelae of the compartment syndrome at their latest review at least six months after injury. A threshold for decompression of 30 mmHg would have indicated that 50 patients (43%) would have required fasciotomy, and at a 40 mmHg threshold 27 (23%) would have been considered for an unnecessary fasciotomy. In our series, the use of a differential pressure of 30 mmHg as a threshold for fasciotomy led to no missed cases of acute compartment syndrome. We recommended that decompression should be performed if the differential pressure level drops to under 30 mmHg.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUSTILO, R. B., & ANDERSON, J. T. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200204000-00029 · Cited by 2,789
GUSTILO, R. B., MENDOZA, R. M., & WILLIAMS, D. N. (1984) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-198408000-00009 · Cited by 2,383
Acute compartment syndromes: diagnosis and treatment with the aid of the wick catheter.
Mubarak, S. J., Owen, C. A., Hargens, A. R., Garetto, L. P., & Akeson, W. H. (1978) · PubMed · Cited by 461
Peripheral nerve-conduction block by high muscle-compartment pressure.
Hargens, A. R., Romine, J. S., Sipe, J. C., Evans, K. L., Mubarak, S. J., & Akeson, W. H. (1979) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197961020-00006 · Cited by 186
Cited by
Björck, M., Earnshaw, J. J., Acosta, S., Bastos Gonçalves, F., Cochennec, F., Debus, E. S., Hinchliffe, R., Jongkind, V., Koelemay, M. J. W., Menyhei, G., et al. (2020) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2019.09.006 · Cited by 544
Diagnosis and treatment of acute extremity compartment syndrome
von Keudell, A. G., Weaver, M. J., Appleton, P. T., Bae, D. S., Dyer, G. S. M., Heng, M., Jupiter, J. B., & Vrahas, M. S. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00277-9 · Cited by 333
Finkemeier, C. G., Schmidt, A. H., Kyle, R. F., Templeman, D. C., & Varecka, T. F. (2000) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200003000-00007 · Cited by 320
Acute Compartment Syndrome in Lower Extremity Musculoskeletal Trauma
Olson, S. A., & Glasgow, R. R. (2005) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200511000-00003 · Cited by 284
Diagnostic Techniques in Acute Compartment Syndrome of the Leg
Shadgan, B., Menon, M., O'Brien, P. J., & Reid, W. D. (2008) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e318183136d · Cited by 179
What is the effect of compartment syndrome and fasciotomies on fracture healing in tibial fractures
Reverte, M. M., Dimitriou, R., Kanakaris, N. K., & Giannoudis, P. V. (2011) · Injury · doi:10.1016/j.injury.2011.09.007 · Cited by 82
Metadata
- Authors
- McQueen, M. M., & Court-Brown, C. M.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1996-01
- Volume
- 78-B
- Issue
- 1
- Pages
- 99-104
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2293334498
- Cited by
- 520
- References
- 4
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.