The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
Number of Polyethylene Particles and Osteolysis in Total Joing Replacements: A Quanatitive Study Using a Tissue-Digestion Method
Open accessAbstract
Our aim was to analyse the influence of the size, shape and number of particles on the pathogenesis of osteolysis. We obtained peri-implant tissues from 18 patients having revision surgery for aseptically loosened Freeman total knee replacements (10), Charnley total hip replacements (3) and Imperial College/London Hospital double-cup surface hip replacements (5). The size and shape of the polyethylene particles were characterised using SEM and their concentration was calculated. The results were analysed with reference to the presence of radiological osteolysis. The concentration of polyethylene particles in 6 areas with osteolysis was significantly higher than that in 12 areas without osteolysis. There were no significant differences between the size and shape of the particles in these two groups. We conclude that the most critical factor in the pathogenesis of osteolysis is the concentration of polyethylene particles accumulated in the tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Metadata
- Authors
- Kobayashi, A., Freeman, M. A. R., Bonfield, W., Kadoya, Y., Yamac, T., Al-Saffar, N., Scott, G., & Revell, P. A.
- Venue
- Journal of Bone and Joint Surgery - British Volume
- Publisher
- British Editorial Society of Bone & Joint Surgery
- Published
- 1997-09-01
- Volume
- 79
- Issue
- 5
- Pages
- 844-848
- ISSN
- 0301-620X (ISSN-L)
- OpenAlex
- W2097613107
- Cited by
- 195
- References
- 1
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Number of Polyethylene Particles and Osteolysis in Total Joing Replacements: A Quanatitive Study Using a Tissue-Digestion Method. https://app.cochat.ai/papers/10.1302/0301-620x.79b5.7602
- The paper
- Kobayashi, A., Freeman, M. A. R., Bonfield, W., Kadoya, Y., Yamac, T., Al-Saffar, N., Scott, G., & Revell, P. A. (1997). Number of Polyethylene Particles and Osteolysis in Total Joing Replacements: A Quanatitive Study Using a Tissue-Digestion Method. Journal of Bone and Joint Surgery - British Volume. https://doi.org/10.1302/0301-620x.79b5.7602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.