High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
We have examined the results obtained with 72 NexGen legacy posterior stabilised-flex fixed total knee replacements in 47 patients implanted by a single surgeon between March 2003 and September 2004. Aseptic loosening of the femoral component was found in 27 (38%) of the replacements at a mean follow-up of 32 months (30 to 48) and 15 knees (21%) required revision at a mean of 23 months (11 to 45). We compared the radiologically-loose and revised knees with those which had remained well-fixed to identify the factors which had contributed to this high rate of aseptic loosening. Post-operatively, the mean maximum flexion was 136° (110° to 140°) in the loosened group and 125° (95° to 140°) in the well-fixed group (independent t-test, p = 0.022). Squatting, kneeling, or sitting cross-legged could be achieved by 23 (85%) of the loosened knees, but only 22 (49%) of the well-fixed knees (chi-squared test, p = 0.001). The loosened femoral components were found to migrate into a more flexed position, but no migration was detected in the well-fixed group. These implants allowed a high degree of flexion, but showed a marked rate of early loosening of the femoral component, which was associated with weight-bearing in maximum flexion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System
Ewald, F. C. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198911000-00003 · Cited by 1,971
Occupational physical activities and osteoarthritis of the knee
Coggon, D., Croft, P., Kellingray, S., Barrett, D., McLaren, M., & Cooper, C. (2000) · Arthritis & Rheumatism · doi:10.1002/1529-0131(200007)43:7<1443::aid-anr5>3.0.co;2-1 · Cited by 376
MULHOLLAND, S. J., & WYSS, U. P. (2001) · International Journal of Rehabilitation Research · doi:10.1097/00004356-200109000-00004 · Cited by 321
Felson, D. T., Hannan, M. T., Naimark, A., Berkeley, J., Gordon, G., Wilson, P. W. F., & Anderson, J. J. (1991) · PubMed · Cited by 315
Tibiofemoral movement 3: full flexion in the living knee studied by MRI
Nakagawa, S., Kadoya, Y., Todo, S., Kobayashi, A., Sakamoto, H., Freeman, M. A. R., & Yamano, Y. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821199 · Cited by 288
Mechanical loads at the knee joint during deep flexion
Nagura, T., Dyrby, C. O., Alexander, E. J., & Andriacchi, T. P. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00178-4 · Cited by 233
Knee Motions During Maximum Flexion in Fixed and Mobile-Bearing Arthroplasties
Banks, S., Bellemans, J., Nozaki, H., Whiteside, L. A., Harman, M., & Hodge, W. A. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000063121.39522.19 · Cited by 211
Zhang, Y., Hunter, D. J., Nevitt, M. C., Xu, L., Niu, J., Lui, L., Yu, W., Aliabadi, P., & Felson, D. T. (2004) · Arthritis & Rheumatism · doi:10.1002/art.20127 · Cited by 153
The Early Results of High-Flex Total Knee Arthroplasty: A Minimum of 2 Years of Follow-up
Huang, H., Su, J. Y., & Wang, G. (2005) · The Journal of Arthroplasty · doi:10.1016/j.arth.2004.09.053 · Cited by 143
Contact stresses in the knee joint in deep flexion
Thambyah, A., Goh, J., & De, S. D. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.09.002 · Cited by 137
Cemented Femoral Component Surface Finish Mechanics
Crowninshield, R. D., Jennings, J. D., Laurent, M. L., & Maloney, W. J. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810000-00010 · Cited by 134
Maximizing flexion after total knee arthroplasty: The need and the pitfalls
Kurosaka, M., Yoshiya, S., Mizuno, K., et al. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.32688 · Cited by 128
Early results of high‐flex total knee arthroplasty: comparison study at 1 year after surgery
Bin, S. I., & Nam, T.-S. (2006) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-006-0202-y · Cited by 123
Li, G., Most, E., Sultan, P. G., Schule, S., Zayontz, S., Park, S.-E., & Rubash, H. E. (2004) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200408000-00017 · Cited by 113
Kinematics of the knee joint in deep flexion: a radiographic assessment
Hefzy, M. S., Kelly, B. P., & Cooke, T. D. V. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00024-1 · Cited by 109
Correlation of maximum flexion with clinical outcome after total knee replacement in Asian patients
Park, K. K., Chang, C. B., Kang, Y. G., Seong, S. C., & Kim, T. K. (2007) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.89b5.18117 · Cited by 103
Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty
Nakayama, K., Matsuda, S., Miura, H., Higaki, H., OTSUKA, K., & Iwamoto, Y. (2005) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.87b4.15684 · Cited by 100
Kinematics of the knee at high flexion angles: An in vitro investigation
Li, G., Zayontz, S., DeFrate, L. E., et al. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(03)00118-9 · Cited by 94
Nagura, T., Matsumoto, H., Kiriyama, Y., Chaudhari, A., & Andriacchi, T. P. (2006) · Journal of Applied Biomechanics · doi:10.1123/jab.22.4.305 · Cited by 91
Stukenborg-Colsman, C. M., Ostermeier, S., Hurschler, C., & Wirth, C. J. (2002) · Acta Orthopaedica Scandinavica · doi:10.1080/000164702321039598 · Cited by 84
Hydroxyapatite-coated total knee replacement: CLINICAL EXPERIENCE AT 10 TO 15 YEARS
Epinette, J.-A., & Manley, M. T. (2007) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.89b1.17864 · Cited by 84
Polymer Insert Stress in Total Knee Designs During High-Flexion Activities: A Finite Element Study
Morra, E. A., & Greenwald, A. S. (2005) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.e.00436 · Cited by 66
Stemmed femoral knee prostheses: Effects of prosthetic design and fixation on bone loss
van Lenthe, H., Willems, M. M. M., Verdonschot, N. J. J., Malefijt, M. C. D. W., & Huiskes, R. (2002) · Acta Orthopaedica Scandinavica · doi:10.3109/17453670209178027 · Cited by 54
Kinematic Analysis of Conventional and High-Flexion Cruciate-Retaining Total Knee Arthroplasties
Most, E., Li, G., Sultan, P. G., Park, S.-E., & Rubash, H. E. (2005) · The Journal of Arthroplasty · doi:10.1016/j.arth.2004.09.034 · Cited by 53
Tradeoffs between motion and stability in posterior substituting knee arthroplasty design
Delp, S. L., Kocmond, J. H., & Stern, S. H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00172-z · Cited by 41
The effect of tibial polyethylene insert design on range of motion
Klein, G. R., Parvizi, J., Rapuri, V. R., Austin, M. S., & Hozack, W. J. (2004) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(04)00374-2 · Cited by 36
Chapman-Sheath, P., Bruce, W. J. M., Chung, W. K., Morberg, P., Gillies, R. J., & Walsh, W. R. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00016-x · Cited by 22
Barink, M., Verdonschot, N. J. J., & Malefijt, M. D. W. (2003) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/095441103770802487 · Cited by 22
Metadata
- Authors
- Han, H. S., Kang, S.-B., & Yoon, K. S.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2007-11
- Volume
- 89-B
- Issue
- 11
- Pages
- 1457-1461
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2132088189
- Cited by
- 169
- References
- 28
- FWCI
- 7.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.