The DOI matches its Crossref record.
Computer navigation versus conventional total knee replacement: NO DIFFERENCE IN FUNCTIONAL RESULTS AT TWO YEARS
Abstract
We previously compared the component alignment in total knee replacement using a computer-navigated technique with a conventional jig-based method. We randomly allocated 71 patients to undergo either computer-navigated or conventional replacement. An improved alignment was seen in the computer-navigated group. The patients were then followed up post-operatively for two years, using the Knee Society score, the Short Form-36 health survey, the Western Ontario and McMaster Universities osteoarthritis index, the Bartlett Patellar pain questionnaire and the Oxford knee score, to assess functional outcome. At two years post-operatively 60 patients were available for assessment, 30 in each group and 62 patients completed a postal survey. No patient in either group had undergone revision. All variables were analysed for differences between the groups either by Student’s t-test or the Mann-Whitney U test. Differences between the two groups did not reach significance for any of the outcome measures at any time point. At two years postoperatively, the frequency of mild to severe anterior pain was not significantly different (p = 0.818), varying between 44% (14) for the computer-navigated group, and 47% (14) for the conventionally-replaced group. The Bartlett Patellar score and the Oxford knee score were also not significantly different (t-test p = 0.161 and p = 0.607, respectively). The clinical outcome of the patients with a computer-navigated knee replacement appears to be no different to that of a more conventional jig-based technique at two years post-operatively, despite the better alignment achieved with computer-navigated surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Effect of Alignment and BMI on Failure of Total Knee Replacement
Ritter, M. A., Davis, K. E., Meding, J. B., Pierson, J. L., Berend, M. E., & Malinzak, R. A. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00772 · Cited by 669
Howell, S. M., Kuznik, K., Hull, M. L., & Siston, R. A. (2008) · Orthopedics · doi:10.3928/01477447-20080901-15 · Cited by 288
Alignment in total knee replacement
Sikorski, J. M. (2008) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.90b9.20793 · Cited by 276
de Steiger, R. N., Liu, Y.-L., & Graves, S. E. (2015) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.m.01496 · Cited by 267
van der List, J. P., Chawla, H., Joskowicz, L., & Pearle, A. D. (2016) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4305-9 · Cited by 200
Metadata
- Authors
- Spencer, J. M., Chauhan, S. K., Sloan, K., Taylor, A., & Beaver, R. J.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2007-04
- Volume
- 89-B
- Issue
- 4
- Pages
- 477-480
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W1601053592
- Cited by
- 187
- References
- 0
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer navigation versus conventional total knee replacement: NO DIFFERENCE IN FUNCTIONAL RESULTS AT TWO YEARS. https://app.cochat.ai/papers/10.1302/0301-620x.89b4.18094
- The paper
- Spencer, J. M., Chauhan, S. K., Sloan, K., Taylor, A., & Beaver, R. J. (2007). Computer navigation versus conventional total knee replacement: NO DIFFERENCE IN FUNCTIONAL RESULTS AT TWO YEARS. The Journal of Bone and Joint Surgery. British volume. https://doi.org/10.1302/0301-620x.89b4.18094
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.