Performance Characteristics of Eight Estradiol Immunoassays
The DOI matches its Crossref record.
Abstract
Measurement of estradiol is useful in assisted reproduction, evaluation of infertility, menopause, and male feminization. The analytic performance of 8 estradiol immunoassays was evaluated. The imprecision and accuracy of the Access, ADVIA Centaur, ARCHITECT i2000, AutoDELFIA, Elecsys 2010, IMMULITE 2000, and Vitros ECi estradiol assays (see text for proprietary information) were evaluated by using an isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) reference method. The coefficient of variation (CV) ranged from 6.9% on the Elecsys 2010 to 42.6% on the ADVIA Centaur at an estradiol concentration of 18 pg/mL (66 pmol/L), with the ARCHITECT i2000 assay in development and the Vitros ECi having a CV below 10% at this estradiol concentration. Agreement between the automated assays and ID-GC-MS was variable, with slopes ranging from 0.87 to 1.20. The Access, ARCHITECT i2000 in development, and the IMMULITE 2000 were the most accurate, with slopes of 0.99, 0.98, and 1.03, respectively. These findings indicate that the ARCHITECT i2000 estradiol assay in development had the best precision and accuracy of the assays evaluated for measurement of serum estradiol concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Challenges to the measurement of estradiol: an Endocrine Society Position Statement
Rosner, W., Hankinson, S. E., Sluss, P. M., Vesper, H. W., & Wierman, M. E. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-3780 · Cited by 408
Stricker, R., Eberhart, R., Chevailler, M.-C., Quinn, F. A., Bischof, P., & Stricker, R. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.160 · Cited by 392
Handelsman, D. J., & Wartofsky, L. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-3375 · Cited by 368
Plasma sex steroid hormones and risk of developing type 2 diabetes in women: a prospective study
Ding, E. L., Song, Y., Manson, J. E., Rifai, N., Buring, J. E., & Liu, S. (2007) · Diabetologia · doi:10.1007/s00125-007-0785-y · Cited by 208
“Among eight different oestradiol assays tested and compared, the Elecsys 2010 assay yielded the smallest coefficient of variation and had the best sensitivity for measuring low oestradiol concentrations [16].”
MethodKrasowski, M. D., Drees, D., Morris, C. S., Maakestad, J., Blau, J. L., & Ekins, S. (2014) · BMC Clinical Pathology · doi:10.1186/1472-6890-14-33 · Cited by 212
“Estradiol immunoassays often do not perform well relative to LC/MS/MS in measuring the lower end of estradiol concentrations found in males, a limitation likely related primarily to differing lower limits of quantitation between the methods [59,62,64,65].”
Metadata
- Authors
- Yang, M., Owen, M., Ramsay, C., Xie, M., & Roberts, M.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-03-01
- Volume
- 122
- Issue
- 3
- Pages
- 332-337
- ISSN
- 0002-9173 (ISSN-L)
- OpenAlex
- W4250557621
- Cited by
- 68
- References
- 0
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance Characteristics of Eight Estradiol Immunoassays. https://app.cochat.ai/papers/10.1309/5n2r-4ht4-gm0a-gpby
- The paper
- Yang, M., Owen, M., Ramsay, C., Xie, M., & Roberts, M. (2004). Performance Characteristics of Eight Estradiol Immunoassays. American Journal of Clinical Pathology. https://doi.org/10.1309/5n2r-4ht4-gm0a-gpby
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.