Evaluation of the New Multiplexed Immunoassay, FIDIS, for Simultaneous Quantitative Determination of Antinuclear Antibodies and Comparison With Conventional Methods
Open accessThe DOI matches its Crossref record.
Abstract
Our study was done to evaluate the FIDIS Connective kit (Biomedical Diagnostics, Marne la Vallée, France) for simultaneous quantitative determination in the same sample of 9 antinuclear antibody specificities directed against double-stranded DNA, SSA, SSB, Sm, Sm/RNP, Scl-70, Jo-1, ribosome, and centromere B and to compare it with standardized commercial methods, enzyme immunoassay and immunofluorescence. FIDIS technology constitutes a new multiplexed method using the Luminex 100 system (Luminex, Austin, TX) based on the use of distinct color-coded particles and flow cytometric detection. Serum samples from people with diagnosed rheumatic diseases with well-identified markers of autoimmunity were tested by a retrospective study. Specificity was assessed by testing blood donors and potential biologic interfering samples. This first evaluation demonstrated the analytic performance of FIDIS technology. Concordances with routine methods were between 99.1% and 100.0% on 222 samples. FIDIS was reliable (coefficients of variation < 10%) and accurate (correlation coefficients with enzyme-linked immunosorbent assay between 0.90 and 0.97) in a large measure range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances and applications of multiplexed diagnostic technologies in autoimmune diseases
Fritzler, M. (2006) · Lupus · doi:10.1191/0961203306lu2327oa · Cited by 78
COPPLE, S. S., MARTINS, T. B., MASTERSON, C., JOLY, E., & HILL, H. R. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1398.052 · Cited by 42
Detection of antibodies to dsDNA: an overview of laboratory assays
Rouquette, A., & Desgruelles, C. (2006) · Lupus · doi:10.1191/0961203306lu2324oa · Cited by 39
Self-citationEvaluation of current methods for the measurement of serum anti double-stranded DNA antibodies
GHIRARDELLO, A., VILLALTA, D., MOROZZI, G., AFELTRA, A., GALEAZZI, M., GERLI, R., MATHIEU, A., MERONI, P. L., MIGLIORINI, P., RADICE, A., et al. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1398.045 · Cited by 35
Metadata
- Authors
- Rouquette, M., Desgruelles, M., & Laroche, P.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-11-01
- Volume
- 120
- Issue
- 5
- Pages
- 676-681
- ISSN
- 0002-9173 (ISSN-L)
- OpenAlex
- W2010088805
- Cited by
- 61
- References
- 0
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the New Multiplexed Immunoassay, FIDIS, for Simultaneous Quantitative Determination of Antinuclear Antibodies and Comparison With Conventional Methods. https://app.cochat.ai/papers/10.1309/gjhk-0d24-yddx-w0nf
- The paper
- Rouquette, M., Desgruelles, M., & Laroche, P. (2003). Evaluation of the New Multiplexed Immunoassay, FIDIS, for Simultaneous Quantitative Determination of Antinuclear Antibodies and Comparison With Conventional Methods. American Journal of Clinical Pathology. https://doi.org/10.1309/gjhk-0d24-yddx-w0nf
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.