An Evaluation of the Roche Cobas c 111
The DOI matches its Crossref record.
Abstract
The cobas c 111, a new low volume bench-top analyzer from Roche Diagnostics (Indianapolis, IN), was evaluated to determine whether the operational and performance characteristics of the system would make it a good fit for the physicians’ office laboratories and hospital stat labs in the Laboratory Corporation of America (LabCorp) network. Twenty-five frequently ordered analytes were evaluated relative to the published specifications of the cobas c 111. Additionally correlation studies, using patient serum samples, were used to determine inter-instrument comparability between 2 cobas c 111 instruments and accuracy relative to the standardized assays at LabCorp. Precision, linearity, method comparison to another large Roche system, inter-instrument comparability, potential carryover, and time to result studies met or exceeded expectations. Additionally, sigma metrics analyses graded the overall performance of this analyzer as world class. The analytical performance, compact size, intuitive operation along with the expected low maintenance and reliability make the cobas c 111 a good fit for the intended small laboratory niche environment at LabCorp.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Levers, K., Dalton, R., Galvan, E., O’Connor, A., Goodenough, C., Simbo, S., Mertens-Talcott, S. U., Rasmussen, C., Greenwood, M., Riechman, S., et al. (2016) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-016-0133-z · Cited by 111
“This analyzer has been known to be highly valid and reliable in previously published reports [31].”
MethodJung, Y. P., Earnest, C. P., Koozehchian, M., Galvan, E., Dalton, R., Walker, D., Rasmussen, C., Murano, P. S., Greenwood, M., & Kreider, R. B. (2017) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-016-0159-2 · Cited by 56
“This analyzer has been known to be highly valid and reliable in previously published reports [51].”
MethodGalvan, E., Walker, D. K., Simbo, S. Y., Dalton, R., Levers, K., O’Connor, A., Goodenough, C., Barringer, N. D., Greenwood, M., Rasmussen, C., et al. (2016) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-016-0124-0 · Cited by 42
Jung, Y. P., Earnest, C. P., Koozehchian, M., Cho, M., Barringer, N., Walker, D., Rasmussen, C., Greenwood, M., Murano, P. S., & Kreider, R. B. (2017) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-016-0158-3 · Cited by 40
Metadata
- Authors
- Bowling, J. L., & Katayev, A.
- Venue
- Laboratory Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-07
- Volume
- 41
- Issue
- 7
- Pages
- 398-402
- ISSN
- 0007-5027 (ISSN-L)
- 1943-7730
- OpenAlex
- W2070857639
- Cited by
- 38
- References
- 0
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Evaluation of the Roche Cobas c 111. https://app.cochat.ai/papers/10.1309/lm6t8d1lkqxvncac
- The paper
- Bowling, J. L., & Katayev, A. (2010). An Evaluation of the Roche Cobas c 111. Laboratory Medicine. https://doi.org/10.1309/lm6t8d1lkqxvncac
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.