Quality Improvement in the Coagulation Laboratory: Reducing the Number of Insufficient Blood Draw Specimens for Coagulation Testing
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To report the efforts of our laboratory to reduce quantity-not-sufficient (QNS) specimens via several methods and to directly measure the effect of expired collection tubes on the amount of blood that can be drawn. METHODS: We tracked the number of QNS venous-blood specimens per month received by our coagulation laboratory from March 2008 to December 2012. Interventions involved communications that informed nurses and phlebotomists how to avoid drawing QNS specimens and floor sweeps, in which laboratory staff searched for and removed expired vacuum-based blood-collection tubes (VBCTs) from inpatient hospital floors. Also, we assessed 11 healthy donors to determine the amount of blood that could be drawn into expired VBCTs. RESULTS: During the study period, the rate of QNS specimens dropped from a mean of 0.7% to 0.3%. In expired VBCTs collected from healthy donors, we observed a statistically significant difference in the amount of blood drawn into nonexpired vs expired VBCTs (P <.001). Also, there was a negative relationship between the number of months that the VBCT had been expired and the amount of blood that could be drawn into the VBCTs (P <.001). For every month that VBCTs were expired, the amount of blood drawn decreased by approximately 1.8 mm (0.1 mL), using linear regression analysis. CONCLUSION: Our evidence strongly suggests that expired VBCTs consistently and progressively yield QNS specimens. Methods to reduce blood draws from expired VBCTs may include communications promoting proper blood draw technique, floor sweeps to remove expired VBCTs, and improved inventory management.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Pre-evacuated blood collection tubes which are beyond the expiry date have a decreased vacuum which may lead to drawing a less than optimal volume of blood and lead to an improper blood to additive ratio [36], [37].”
From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [36]
Citations
Cites
Errors in a Stat Laboratory: Types and Frequencies 10 Years Later
Carraro, P., & Plebani, M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.088344 · Cited by 670
Mistakes in a stat laboratory: types and frequency
Plebani, M., & Carraro, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1348 · Cited by 572
Plotting basic control charts: tutorial notes for healthcare practitioners
Mohammed, M. A., Worthington, P., & Woodall, W. H. (2008) · Quality and Safety in Health Care · doi:10.1136/qshc.2004.012047 · Cited by 243
Quality Standards for Sample Collection in Coagulation Testing
Lippi, G., Salvagno, G., Montagnana, M., Lima-Oliveira, G., Guidi, G., & Favaloro, E. (2012) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0032-1315961 · Cited by 196
Risk management in the preanalytical phase of laboratory testing
Lippi, G., & Guidi, G. C. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.167 · Cited by 176
Adcock, D. M., Kressin, D. C., & Marlar, R. A. (1998) · American Journal of Clinical Pathology · doi:10.1093/ajcp/109.5.595 · Cited by 120
Preanalytic Error Tracking in a Laboratory Medicine Department: Results of a 1-Year Experience
Lippi, G., Bassi, A., Brocco, G., Montagnana, M., Salvagno, G. L., & Guidi, G. C. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.069534 · Cited by 114
Outpatient Phlebotomy Success and Reasons for Specimen Rejection
Dale, J. C., & Novis, D. A. (2002) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2002-126-0416-opsarf · Cited by 105
Problems in Laboratory Testing in Primary Care
Nutting, P. A. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03530320059035 · Cited by 97
Quality and reliability of routine coagulation testing: can we trust that sample?
Lippi, G., Franchini, M., Montagnana, M., Salvagno, G. L., Poli, G., & Guidi, G. C. (2006) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000245290.57021.46 · Cited by 89
Research works printed but not linked: 3
- Breyfogle FW . Lean and its Integration with S4/IEE: Implementing Six Sigma. Hoboken, NJ: John Wiley & Sons, Inc; 2003:876–877.
- [No authors listed.] Selecting the best error-prevention tools for the job. ISMP Medication Safety Alert! Community/Ambulatory Care Edition.2006;5(2):1–2.
- Clinical and Laboratory Standards Institute . Collection, Transport, and Processing Of Blood Specimens for Testing Plasma-Based Coagulation Assays and Molecular Hemostasis Assays; Approved Guideline. Fifth Edition. Wayne PA: Clinical and Laboratory Standards Institute; CLSI document H21-A5; 2008.
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Joint EFLM-COLABIOCLI recommendation for venous blood sampling
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2019) · Annales de biologie clinique · doi:10.1684/abc.2019.1419 · Cited by 40
Radovanović, P. B. (2020) · Biochemia Medica · doi:10.11613/bm.2020.020708 · Cited by 11
Winter, W. E., Pittman, D. L., & Harris, N. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.11.012 · Cited by 10
Plasma for Laboratory Diagnostics
Šepetienė, R., Sidlauskiene, R., & Patamsytė, V. (2018) · InTech eBooks · doi:10.5772/intechopen.76092 · Cited by 9
Metadata
- Authors
- Bostic, G., Thompson, R., Atanasoski, S., Canlas, C., Ye, H., Kolins, M., & Smith, M. D.
- Affiliations
- Corewell Health William Beaumont University Hospital (US)
- Corresponding author
- Smith, Marc D.
- ORCID
- Ye, Hong
- Venue
- Laboratory Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-11-01
- Volume
- 46
- Issue
- 4
- Pages
- 347-355
- ISSN
- 0007-5027 (ISSN-L)
- 1943-7730
- OpenAlex
- W2174542483
- Semantic Scholar
- a2b9f216915c9624493f2748008a9a2f8645de81
- Cited by
- 14
- References
- 20
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 1 · 2020: 1 · 2019: 4 · 2018: 2
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Laboratory Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Health Professions › General Health Professions › Healthcare cost, quality, practices
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Quality and Management
- Keywords
- coagulation tests, phlebotomy, inventory management, quality improvement
- MeSH terms
- Blood Coagulation Tests, Blood Specimen Collection, Humans, Laboratories, Quality Improvement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality Improvement in the Coagulation Laboratory: Reducing the Number of Insufficient Blood Draw Specimens for Coagulation Testing. https://app.cochat.ai/papers/10.1309/lma4wyn3xfukelbd
- The paper
- Bostic, G., Thompson, R., Atanasoski, S., Canlas, C., Ye, H., Kolins, M., & Smith, M. D. (2015). Quality Improvement in the Coagulation Laboratory: Reducing the Number of Insufficient Blood Draw Specimens for Coagulation Testing. Laboratory Medicine. https://doi.org/10.1309/lma4wyn3xfukelbd
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.