The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Quality Standards for Sample Collection in Coagulation Testing
Abstract
Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of a light meal on routine haematological tests.
(2010) · PubMed Central · doi:10.2450/2009.0142-09 · Cited by 71
Self-citationShort-term venous stasis influences routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000178828.59866.03 · Cited by 66
Self-citationElimination of the venous stasis error for routine coagulation testing by transillumination
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.04.008 · Cited by 38
Self-citationTo mix or not to mix venous blood samples collected in vacuum tubes?
Parenmark, A., & Landberg, E. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.705 · Cited by 33
Discard tubes are not necessary when drawing samples for specialized coagulation testing
Smock, K. J., Crist, R. A., Hansen, S. J., Rodgers, G. M., & Lehman, C. M. (2010) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e3283380d12 · Cited by 22
Influence of primary sample mixing on routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2007) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e32828621a0 · Cited by 18
Self-citation
Cited by
Lippi, G., von Meyer, A., Cadamuro, J., & Simundic, A.-M. (2019) · Diagnosis · doi:10.1515/dx-2018-0018 · Cited by 135
Self-citationKershaw, G., Mohammed, S., Lippi, G., & Favaloro, E. (2019) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0038-1677018 · Cited by 96
Self-citationSimundic, A.-M., Cornes, M., Grankvist, K., Lippi, G., Nybo, M., Kovalevskaya, S., Sprongl, L., Sumarac, Z., & Church, S. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0283 · Cited by 84
Self-citationLippi, G., Cervellin, G., & Mattiuzzi, C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.022 · Cited by 66
“Among various preanalytical non-conformances that can be encountered in routine laboratory practice, sample hemolysis represents the primary source of problems, in terms of prevalence and likelihood of sample rejection (3,4).”
BackgroundSelf-citationIncorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.026 · Cited by 33
Self-citation
Metadata
- Authors
- Lippi, G., Salvagno, G., Montagnana, M., Lima-Oliveira, G., Guidi, G., & Favaloro, E.
- Venue
- Seminars in Thrombosis and Hemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 2012-06-05
- Volume
- 38
- Issue
- 06
- Pages
- 565-575
- ISSN
- 0094-6176 (ISSN-L)
- 1098-9064
- OpenAlex
- W2051731532
- Cited by
- 196
- References
- 6
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality Standards for Sample Collection in Coagulation Testing. https://app.cochat.ai/papers/10.1055/s-0032-1315961
- The paper
- Lippi, G., Salvagno, G., Montagnana, M., Lima-Oliveira, G., Guidi, G., & Favaloro, E. (2012). Quality Standards for Sample Collection in Coagulation Testing. Seminars in Thrombosis and Hemostasis. https://doi.org/10.1055/s-0032-1315961
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.