The DOI matches its Crossref record; 91 of the 91 references it cites were found in a registry or an index.
Poststroke Upper Extremity Rehabilitation: A Review of Robotic Systems and Clinical Results
Abstract
Although the use of robotic devices to address neuromuscular rehabilitative goals represents a promising technological advance in medical care, the large number of systems being developed and varying levels of clinical study of the devices make it difficult to follow and interpret the results in this new field. This article is a review of the current state-of-the-art in robotic applications in poststroke therapy for the upper extremity, written specifically to help clinicians determine the differences between various systems. We concentrate primarily on systems that have been tested clinically. Robotic systems are grouped by rehabilitation application (e.g., gross motor movement, bilateral training, etc.), and, where possible, the neurorehabilitation strategies employed by each system are described. We close with a discussion of the benefits and concerns of using robotics in rehabilitation and an indication of challenges that must be addressed for therapeutic robots to be applied practically in the clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Motor learning: its relevance to stroke recovery and neurorehabilitation
Krakauer, J. W. (2006) · Current Opinion in Neurology · doi:10.1097/01.wco.0000200544.29915.cc · Cited by 1,275
Taub, E., Uswatte, G., & Pidikiti, R. D. (1999) · PubMed · Cited by 1,168
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 3×
“The MIME system described previously also has a passive mode that moves the subject’s arm along a specific, desired trajectory.(24,25,34) The REHAROB system uses industrial robots to passively move the upper limb with the goal of decreasing spasticity.”
MethodChollet, F., Di Piero, V., Wise, R. J. S., Brooks, D. J., Dolan, R. J., & Frackowiak, R. S. J. (1991) · Annals of Neurology · doi:10.1002/ana.410290112 · Cited by 1,098
Neural correlates of motor recovery after stroke: a longitudinal fMRI study
Ward, N. S. (2003) · Brain · doi:10.1093/brain/awg245 · Cited by 1,006
Movement Smoothness Changes during Stroke Recovery
Rohrer, B., Fasoli, S., Krebs, H. I., Hughes, R., Volpe, B., Frontera, W. R., Stein, J., & Hogan, N. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-18-08297.2002 · Cited by 767
(2006) · Springer eBooks · doi:10.1007/0-387-28287-4 · Cited by 717
Rehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714 · cited 3×
“As the field has progressed, Krebs et al.(91) have suggested that therapy should be adjusted based on the abilities of the individual.”
BackgroundInfluentialMotor cortex plasticity during constraint-induced movement therapy in stroke patients
Liepert, J., Miltner, W. H. R., Bauder, H., Sommer, M., Dettmers, C., Taub, E., & Weiller, C. (1998) · Neuroscience Letters · doi:10.1016/s0304-3940(98)00386-3 · Cited by 693
Cited by
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Klamroth-Marganska, V., Blanco, J., Campen, K., Curt, A., Dietz, V., Ettlin, T., Felder, M., Fellinghauer, B., Guidali, M., Kollmar, A., et al. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70305-3 · Cited by 522
Soft robotic devices for hand rehabilitation and assistance: a narrative review
Chu, C.-Y., & Patterson, R. M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0350-6 · Cited by 320
Metadata
- Authors
- Brewer, B. R., McDowell, S. K., & Worthen-Chaudhari, L. C.
- Venue
- Topics in Stroke Rehabilitation
- Publisher
- Informa UK Limited
- Published
- 2007-12
- Volume
- 14
- Issue
- 6
- Pages
- 22-44
- ISSN
- 1074-9357 (ISSN-L)
- 1945-5119
- OpenAlex
- W2081519959
- Cited by
- 301
- References
- 91
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.