Polyaniline. Preparation of a conducting polymer(IUPAC Technical Report)
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Eight persons from five institutions in different countries carried out polymerizations of aniline following the same preparation protocol. In a "standard" procedure, aniline hydrochloride was oxidized with ammonium peroxydisulfate in aqueous medium at ambient temperature. The yield of polyaniline was higher than 90 % in all cases. The electrical conductivity of polyaniline hydrochloride thus prepared was 4.4 ± 1.7 S cm-1 (average of 59 samples), measured at room temperature. A product with defined electrical properties could be obtained in various laboratories by following the same synthetic procedure. The influence of reduced reaction temperature and increased acidity of the polymerization medium on polyaniline conductivity were also addressed. The conductivity changes occurring during the storage of polyaniline were monitored. The density of polyaniline hydrochloride was 1.329 g cm-3. The average conductivity of corresponding polyaniline bases was 1.4 x108 S cm-1, the density being 1.245 g cm-1. Additional changes in the conductivity take place during storage. Aging is more pronounced in powders than in compressed samples. As far as aging effects are concerned, their assessment is relative. The observed reduction in the conductivity by ~10 % after more than one-year storage is large but, compared with the low conductivity of corresponding polyaniline (PANI) base, such a change is negligible. For most applications, an acceptable level of conductivity may be maintained throughout the expected lifetime.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of organic conductive molecules and polymers
Nalwa, H. S. (1997) · Cited by 2,786
Cited by
Conducting-polymer-based supercapacitor devices and electrodes
Snook, G. A., Kao, P., & Best, A. S. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2010.06.084 · Cited by 3,724
Graphene-based polymer nanocomposites
Potts, J. R., Dreyer, D. R., Bielawski, C. W., & Ruoff, R. S. (2011) · Polymer · doi:10.1016/j.polymer.2010.11.042 · Cited by 3,123
Progress in preparation, processing and applications of polyaniline
Bhadra, S., Khastgir, D., Singha, N. K., & Lee, J. H. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.04.003 · Cited by 1,910
A General Chemical Route to Polyaniline Nanofibers
Huang, J., & Kaner, R. B. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0371754 · Cited by 1,369
Polyaniline nanostructures and the role of aniline oligomers in their formation
Stejskal, J., Sapurina, I., & Trchová, M. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.07.006 · Cited by 799
Self-citation
Metadata
- Authors
- Stejskal, J., & Gilbert, R. G.
- Venue
- Pure and Applied Chemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 2002-01-01
- Volume
- 74
- Issue
- 5
- Pages
- 857-867
- ISSN
- 0033-4545 (ISSN-L)
- 1365-3075
- OpenAlex
- W2096507625
- Cited by
- 1,392
- References
- 1
- FWCI
- 23.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.