Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

An Improved Segmentation Method for In Vivo μCT Imaging

Waarsing, Jan H, Day, Judd S, Weinans, Harrie · 2004 · Journal of Bone and Mineral Research

Abstract

Image segmentation methods for μCT can influence the accuracy of bone morphometry calculations. A new automated segmentation method is introduced, and its performance is compared with standard segmentation methods. The new method can improve the results of in vivo μCT, where the need to keep radiation dose low limits scan quality. Introduction: An important topic for μCT analysis of bone samples is the segmentation of the original reconstructed grayscale data sets to separate bone from non-bone. Problems like noise, resolution limitations, and beam-hardening make this a nontrivial issue. Inappropriate segmentation methods will reduce the potential power of μCT and may introduce bias in the architectural measurements, in particular, when new in vivo μCT with its inherent limitations in scan quality is used. Here we introduce a new segmentation method using local thresholds and compare its performance to standard global segmentation methods. Material and Methods: The local threshold method was validated by comparing the result of the segmentation with histology. Furthermore, the effect of choosing this new method versus standard segmentation methods using global threshold values was investigated by studying the sensitivity of these methods to signal to noise ratio and resolution. Results: Using the new method on high-quality scans yielded accurate results and virtually no differences between histology and the segmented data sets could be observed. When prior knowledge about the volume fraction of the bone was available the global threshold also resulted in appropriate results. Degrading the scan quality had only minor effects on the performance of the new segmentation method. Although global segmentation methods were not sensitive to noise, it was not possible to segment both lower mineralized thin trabeculae and the higher mineralized cortex correctly with the same threshold value. Conclusion: At high resolutions, both the new local and conventional global segmentation methods gave near exact representations of the bone structure. When scanned samples are not homogenous (e.g., thick cortices and thin trabeculae) and when resolution is relatively low, the local segmentation method outperforms global methods. It maximizes the potential of in vivo μCT by giving good structural representation without the need to use longer scanning times that would increase absorption of harmful X-ray radiation by the living tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1359/jbmr.040705

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 212

Metadata

Authors
Waarsing, J. H., Day, J. S., & Weinans, H.
Venue
Journal of Bone and Mineral Research
Published
2004-10-01
Volume
19
Issue
10
Pages
1640-1650
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2042426452
Cited by
212
References
2
FWCI
7.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Improved Segmentation Method for In Vivo μCT Imaging. https://app.cochat.ai/papers/10.1359/jbmr.040705
The paper
Waarsing, J. H., Day, J. S., & Weinans, H. (2004). An Improved Segmentation Method for In Vivo μCT Imaging. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.040705

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.