The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Complete Volumetric Decomposition of Individual Trabecular Plates and Rods and Its Morphological Correlations With Anisotropic Elastic Moduli in Human Trabecular Bone
Open accessAbstract
Trabecular plates and rods are important microarchitectural features in determining mechanical properties of trabecular bone. A complete volumetric decomposition of individual trabecular plates and rods was used to assess the orientation and morphology of 71 human trabecular bone samples. The ITS-based morphological analyses better characterize microarchitecture and help predict anisotropic mechanical properties of trabecular bone. Introduction: Standard morphological analyses of trabecular architecture lack explicit segmentations of individual trabecular plates and rods. In this study, a complete volumetric decomposition technique was developed to segment trabecular bone microstructure into individual plates and rods. Contributions of trabecular type-associated morphological parameters to the anisotropic elastic moduli of trabecular bone were studied. Materials and Methods: Seventy-one human trabecular bone samples from the femoral neck (FN), tibia, and vertebral body (VB) were imaged using μCT or serial milling. Complete volumetric decomposition was applied to segment trabecular bone microstructure into individual plates and rods. The orientation of each individual trabecula was determined, and the axial bone volume fractions (aBV/TV), axially aligned bone volume fraction along each orthotropic axis, were correlated with the elastic moduli. The microstructural type-associated morphological parameters were derived and compared with standard morphological parameters. Their contributions to the anisotropic elastic moduli, calculated by finite element analysis (FEA), were evaluated and compared. Results: The distribution of trabecular orientation suggested that longitudinal plates and transverse rods dominate at all three anatomic sites. aBV/TV along each axis, in general, showed a better correlation with the axial elastic modulus (r2 = 0.95∼0.99) compared with BV/TV (r2 = 0.93∼0.94). The plate-associated morphological parameters generally showed higher correlations with the corresponding standard morphological parameters than the rod-associated parameters. Multiple linear regression models of six elastic moduli with individual trabeculae segmentation (ITS)-based morphological parameters (adjusted r2 = 0.95∼0.98) performed equally well as those with standard morphological parameters (adjusted r2 = 0.94∼0.97) but revealed specific contributions from individual trabecular plates or rods. Conclusions: The ITS-based morphological analyses provide a better characterization of the morphology and trabecular orientation of trabecular bone. The axial loading of trabecular bone is mainly sustained by the axially aligned trabecular bone volume. Results suggest that trabecular plates dominate the overall elastic properties of trabecular bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationLiu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., & Guo, X. E. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060716 · Cited by 207
Self-citationZhang, X. H., Liu, X. S., Vasilic, B., Wehrli, F. W., Benito, M., Rajapakse, C. S., Snyder, P. J., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080405 · Cited by 79
Self-citationUniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170418 · Cited by 77
Self-citation
Cited by
Whittier, D. E., Boyd, S. K., Burghardt, A. J., Paccou, J., Ghasem-Zadeh, A., Chapurlat, R., Engelke, K., & Bouxsein, M. L. (2020) · Osteoporosis International · doi:10.1007/s00198-020-05438-5 · Cited by 370
A survey on skeletonization algorithms and their applications
Saha, P. K., Borgefors, G., & Sanniti di Baja, G. (2016) · Pattern Recognition Letters · doi:10.1016/j.patrec.2015.04.006 · Cited by 353
Self-citationHigh-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Quantitative imaging techniques for the assessment of osteoporosis and sarcopenia
Guerri, S., Mercatelli, D., Aparisi Gómez, M. P., Napoli, A., Battista, G., Guglielmi, G., & Bazzocchi, A. (2018) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2018.01.05 · Cited by 169
Zhang, X. H., Liu, X. S., Vasilic, B., Wehrli, F. W., Benito, M., Rajapakse, C. S., Snyder, P. J., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080405 · Cited by 79
Self-citation
Metadata
- Authors
- Liu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., Bevill, G., Keaveny, T. M., & Guo, X. E.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-02-01
- Volume
- 23
- Issue
- 2
- Pages
- 223-235
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W1993457878
- Cited by
- 239
- References
- 4
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complete Volumetric Decomposition of Individual Trabecular Plates and Rods and Its Morphological Correlations With Anisotropic Elastic Moduli in Human Trabecular Bone. https://app.cochat.ai/papers/10.1359/jbmr.071009
- The paper
- Liu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., Bevill, G., Keaveny, T. M., & Guo, X. E. (2008). Complete Volumetric Decomposition of Individual Trabecular Plates and Rods and Its Morphological Correlations With Anisotropic Elastic Moduli in Human Trabecular Bone. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.071009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.