Effects of a New Positioner on the Precision of Hip Bone Mineral Density Measurements
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In an attempt to reduce patient positioning errors, the authors tested the use of a new hip-specific positioning tool, OsteoDyne's Hip Positioner System (HPS). The HPS is an “A” frame splint designed to abduct both legs approximately 15° to hold them in full extension at the hips and knees and to lock the feet in a neutral position. Seventy volunteer women aged 35–82 years were randomly assigned in two age-matched groups (mean age 56 years). Each group underwent two consecutive femur dual X-ray absorptiometry (DXA) scans with intermediate repositioning using the HPS system and two others utilizing the standard hip positioner provided with Hologic and Lunar scanners. One technician performed all scans using a Hologic QDR 1000-Plus and Lunar DPX-Plus densitometer. One hundred and fifty volunteer women aged 50–84 years (mean age, 64 years) were recruited in a multicenter study for the assessment of precision. Each subject underwent three consecutive femur DXA scans with intermediate repositioning using the HPS system. The coefficient of variation (CV) was significantly improved at the femoral neck by the use of the HPS with 0.7 versus 1.2 with the Hologic densitometer but only moderately altered at other sites. Similar results were found with the Lunar densitometer with improvement of precision at the femoral neck, 0.8 versus 1.8 with a similar trend but no significant difference at the other regions. No statistical difference was noted between the femoral neck BMD measured with the HPS system and with the standard positioners in either group. The mean precision of data obtained on the QDR 1000+ was 0.8% (range 0.1–1.4) for the femoral neck BMD, 1.1% (range 0.1–3.0) for the trochanter BMD, 2.3% (range 0.2–5.2) for Ward's triangle BMD, and 0.8% (range 0.1–1.9) for the total femur BMD. The mean precision of data obtained on the QDR 2000 was 0.7% (range 0.1–2), 1% (range 0.1–4.9), 2.6% (range 0.3–5.7), and 0.7% (range 0.1–1.8), respectively. In conclusion, data obtained with the new OsteoDyne's HPS seem capable of reducing patient positioning errors for the hip measurement. Its use is likely to improve confidence in hip bone mineral density measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone density at various sites for prediction of hip fractures
Cummings, S. R., Browner, W., Cummings, S. R., Black, D. M., Nevitt, M. C., Browner, W., Genant, H. K., Cauley, J., Ensrud, K., Scott, J., et al. (1993) · The Lancet · doi:10.1016/0140-6736(93)92555-8 · Cited by 2,446
Cited by
Black, D. M., Schwartz, A. V., Ensrud, K. E., Cauley, J. A., Levis, S., Quandt, S. A., Satterfield, S., Wallace, R. B., Bauer, D. C., Palermo, L., et al. (2006) · JAMA · doi:10.1001/jama.296.24.2927 · Cited by 1,407
Chapuy, M. C., Pamphile, R., Paris, E., Kempf, C., Schlichting, M., Arnaud, S., Garnero, P., Garnero, P., & Meunier, P. J. (2002) · Osteoporosis International · doi:10.1007/s001980200023 · Cited by 549
Self-citationSzulc, P., Beck, T. J., Marchand, F., & Delmas, P. D. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.041230 · Cited by 284
“The OsteoDyne Hip Positioner System (HPS) was used to minimize hip positioning error.((23)) The rectangle of femoral neck was positioned manually perpendicularly to the axis of femoral neck to cover its narrowest part.”
MethodHormone Predictors of Bone Mineral Density Changes during the Menopausal Transition
Sowers, M. R., Jannausch, M., McConnell, D., Little, R., Greendale, G. A., Finkelstein, J. S., Neer, R. M., Johnston, J., & Ettinger, B. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-1836 · Cited by 247
“Osteodyne (Research Triangle Park, NC) positioning devices were used to optimize reproducibility of hip measurements (22).”
MethodSowers, M. R., Finkelstein, J. S., Ettinger, B., Bondarenko, I., Neer, R. M., Cauley, J. A., Sherman, S., & Greendale, G. A. (2003) · Osteoporosis International · doi:10.1007/s00198-002-1307-x · Cited by 164
“Each site used Osteodyne positioning devices to facilitate the reproducible measurement of the proximal femur [21].”
Method
Metadata
- Authors
- Hans, D., Duboeuf, F., Schott, A. M., Horn, S., Avioli, L. V., Drezner, M. K., & Meunier, P. J.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-08-01
- Volume
- 12
- Issue
- 8
- Pages
- 1289-1294
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W1990941484
- Cited by
- 44
- References
- 1
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of a New Positioner on the Precision of Hip Bone Mineral Density Measurements. https://app.cochat.ai/papers/10.1359/jbmr.1997.12.8.1289
- The paper
- Hans, D., Duboeuf, F., Schott, A. M., Horn, S., Avioli, L. V., Drezner, M. K., & Meunier, P. J. (1997). Effects of a New Positioner on the Precision of Hip Bone Mineral Density Measurements. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.1997.12.8.1289
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.