Universal Standardization of Bone Density Measurements: A Method with Optimal Properties for Calibration Among Several Instruments
The DOI matches its Crossref record.
Abstract
The International Dual-Photon X-Ray Absorptiometry (DXA) Standardization Committee (IDSC) conducted a cross-calibration study among three models of DXA machines from three different manufacturers. In that study, 100 subjects were scanned on all three machines. A set of equations were derived to convert bone mineral density (BMD) on each machine to a “standardized BMD” (sBMD) such that sBMD from the same subject derived from different machines would be approximately the same. In a reanalysis of the cross-calibration data, we showed that the conversion method used in the IDSC study did not achieve several optimal properties desirable in such conversions. We derived new conversion equations to sBMD based on minimizing differences among sBMD from the three machines. More important is that the new conversions have no residual bias that was present in the IDSC conversions. The performance of the methods were compared on the cross-calibration data as well as an external data set. We conclude that the IDSC conversions are adequate for clinical use on other machines worldwide, but that researchers should standardize their own machines in a laboratory using the new method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Papaioannou, A., Morin, S., Cheung, A. M., Atkinson, S., Brown, J. P., Feldman, S., Hanley, D. A., Hodsman, A., Jamal, S. A., Kaiser, S. M., et al. (2010) · Canadian Medical Association Journal · doi:10.1503/cmaj.100771 · Cited by 1,749
Intravenous Zoledronic Acid in Postmenopausal Women with Low Bone Mineral Density
Reid, I. R., Brown, J. P., Burckhardt, P., Horowitz, Z., Richardson, P., Trechsel, U., Widmer, A., Devogelaer, J.-P., Kaufman, J.-M., Jaeger, P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011807 · Cited by 877
Quantitative ultrasound of the heel and fracture risk assessment: An updated meta-analysis
Moayyeri, A., Adams, J. E., Adler, R. A., Krieg, M.-A., Hans, D., Compston, J., & Lewiecki, E. M. (2012) · Osteoporosis International · doi:10.1007/s00198-011-1817-5 · Cited by 266
Panach, L., Serna, E., Tarín, J. J., Cano, A., & García-Pérez, M. Á. (2017) · Osteoporosis International · doi:10.1007/s00198-017-4061-9 · Cited by 13
Metadata
- Authors
- Hui, S. L., Gao, S., Zhou, X.-H., Johnston, C. C., Lu, Y., Glüer, C. C., Grampp, S., & Genant, H.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-09-01
- Volume
- 12
- Issue
- 9
- Pages
- 1463-1470
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2153088288
- Cited by
- 229
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Universal Standardization of Bone Density Measurements: A Method with Optimal Properties for Calibration Among Several Instruments. https://app.cochat.ai/papers/10.1359/jbmr.1997.12.9.1463
- The paper
- Hui, S. L., Gao, S., Zhou, X.-H., Johnston, C. C., Lu, Y., Glüer, C. C., Grampp, S., & Genant, H. (1997). Universal Standardization of Bone Density Measurements: A Method with Optimal Properties for Calibration Among Several Instruments. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.1997.12.9.1463
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.