Quantitative ultrasound of the heel and fracture risk assessment: an updated meta-analysis

The DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.

Abstract

Unlabelled Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00198-011-1817-5

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 51 references

Cited by

See all 293

Metadata

Authors
Moayyeri, A., Adams, J. E., Adler, R. A., Krieg, M.-A., Hans, D., Compston, J., & Lewiecki, E. M.
Affiliations
  • University of Cambridge (GB)
  • Manchester Royal Infirmary (GB)
  • Virginia Commonwealth University (US)
  • Centre Hospitalier Universitaire Vaudois (CH)
  • Cambridge University Hospitals NHS Foundation Trust (GB)
  • New Mexico Clinical Research & Osteoporosis Center (US)
Corresponding author
Lewiecki, E. M.
Venue
Osteoporosis International
Published
2011-10-27
Volume
23
Issue
1
Pages
143-153
ISSN
  • 0937-941X (ISSN-L)
  • 1433-2965
OpenAlex
W1988488550
Cited by
266
References
52
Citations by year
2026: 12 · 2025: 13 · 2024: 9 · 2023: 26 · 2022: 10 · 2021: 17 · 2020: 22 · 2019: 11 · 2018: 24 · 2017: 24 · 2016: 21 · 2015: 21 · 2014: 21 · 2013: 17 · 2012: 17
FWCI
18.98
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Osteoporosis International (publishedVersion)
  • PubMed (publishedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • IRIS (submittedVersion)
  • Research Portal (King's College London) (submittedVersion)
  • SERVAL (Université de Lausanne) (submittedVersion)
Funders
Baoji University of Arts And Sciences
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Health Sciences › Medicine › Surgery › Hip and Femur Fractures
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
Keywords
quantitative ultrasound, fracture risk prediction, calcaneus, broadband ultrasound attenuation, sound velocity, stiffness index, hip fracture, vertebral fractures, osteoporotic fractures, bone mineral density, elderly men and women, fracture risk assessment tools, device comparison, osteoporosis screening, fracture prevention
MeSH terms
Aged, Calcaneus, Female, Humans, Male, Middle Aged, Osteoporosis, Prognosis, Ultrasonography, Absorptiometry, Photon, Bone Density, Osteoporosis, Postmenopausal, Risk Assessment, Osteoporotic Fractures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative ultrasound of the heel and fracture risk assessment: an updated meta-analysis. https://app.cochat.ai/papers/10.1007/s00198-011-1817-5
The paper
Moayyeri, A., Adams, J. E., Adler, R. A., Krieg, M.-A., Hans, D., Compston, J., & Lewiecki, E. M. (2012). Quantitative ultrasound of the heel and fracture risk assessment: an updated meta-analysis. Osteoporosis International. https://doi.org/10.1007/s00198-011-1817-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.