CoChat

Measurement of Midfemoral Shaft Geometry: Repeatability and Accuracy Using Magnetic Resonance Imaging and Dual-Energy X-ray Absorptiometry

Open access
Woodhead, Helen J., Kemp, Allan F., Blimkie, Cameron J. R., Briody, Julie N., Duncan, Craig S., Thompson, Madeleine, Lam, Albert, Howman-Giles, Robert, Cowell, Christopher T. · 2001 · Journal of Bone and Mineral Research
Cited by 53

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Although macroscopic geometric architecture is an important determinant of bone strength, there is limited published information relating to the validation of the techniques used in its measurement. This study describes new techniques for assessing geometry at the midfemur using magnetic resonance imaging (MRI) and dual-energy X-ray absorptiometry (DXA) and examines both the repeatability and the accuracy of these and previously described DXA methods. Contiguous transverse MRI (Philips 1.5T) scans of the middle one-third femur were made in 13 subjects, 3 subjects with osteoporosis. Midpoint values for total width (TW), cortical width (CW), total cross-sectional area (TCSA), cortical cross-sectional area (CCSA), and volumes from reconstructed three-dimensional (3D) images (total volume [TV] and cortical volume [CVol]) were derived. Midpoint TW and CW also were determined using DXA (Lunar V3.6, lumbar software) by visual and automated edge detection analysis. Repeatability was assessed on scans made on two occasions and then analyzed twice by two independent observers (blinded), with intra- and interobserver repeatability expressed as the CV (CV ± SD). Accuracy was examined by comparing MRI and DXA measurements of venison bone (and Perspex phantom for MRI), against “gold standard” measures made by vernier caliper (width), photographic image digitization (area) and water displacement (volume). Agreement between methods was analyzed using mean differences (MD ± SD%). MRI CVs ranged from 0.5 ± 0.5% (TV) to 3.1 ± 3.1% (CW) for intraobserver and 0.55 ± 0.5% (TV) to 3.6 ± 3.6% (CW) for interobserver repeatability. DXA results ranged from 1.6 ± 1.5% (TW) to 4.4 ± 4.5% (CW) for intraobserver and 3.8 ± 3.8% (TW) to 8.3 ± 8.1% (CW) for interobserver variation. MRI accuracy was excellent for TV (3.3 ± 6.4%), CVol (3.5 ± 4.0%), TCSA (1.8 ± 2.6%), and CCSA (1.6 ± 4.2%) but not TW (4.1 ± 1.4%) or CW (16.4 ± 14.9%). DXA results were TW (6.8 ± 2.7%) and CW (16.4 ± 17.0%). MRI measures of geometric parameters of the midfemur are highly accurate and repeatable, even in osteoporosis. Both MRI and DXA techniques have limited value in determining cortical width. MRI may prove valuable in the assessment of surface-specific bone accrual and resorption responses to disease, therapy, and variations in mechanical loading.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1359/jbmr.2001.16.12.2251

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 53

Metadata

Authors
Woodhead, H. J., Kemp, A. F., Blimkie, C. J. R., Briody, J. N., Duncan, C. S., Thompson, M., Lam, A., Howman-Giles, R., & Cowell, C. T.
Venue
Journal of Bone and Mineral Research
Published
2001-12-01
Volume
16
Issue
12
Pages
2251-2259
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2013195869
Cited by
53
References
2
FWCI
2.86
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.