The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
New measurement system for fault location in optical waveguide devices based on an interferometric technique
Abstract
A new measurement system for fault location in optical waveguide devices is presented. The system consists of a fiber-optic Mach-Zehnder and a bulk-type Michelson interferometers. The spatial resolution of the scatter distribution is <380 microm, which is limited by the averaging time. The minimum detectable backscattered power is -116 dB relative to the light power propagating in the waveguides. Preliminary experimental results using single-mode fibers <10 cm long are demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiber waveguides: a novel technique for investigating attenuation characteristics
Barnoski, M. K., & Jensen, S. M. (1976) · Applied Optics · doi:10.1364/ao.15.002112 · Cited by 568
Optical waveguiding layers in LiNbO3 and LiTaO3
Kaminow, I. P., & Carruthers, J. R. (1973) · Applied Physics Letters · doi:10.1063/1.1654657 · Cited by 324
Low-loss high-silica single-mode channel waveguides
Takato, N., Yasu, M., & Kawachi, M. (1986) · Electronics Letters · doi:10.1049/el:19860220 · Cited by 70
Cited by
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Metadata
- Authors
- Takada, K., Yokohama, I., Chida, K., & Noda, J.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1987-05-01
- Volume
- 26
- Issue
- 9
- Pages
- 1603
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2056433442
- Cited by
- 371
- References
- 3
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.