Cited by 10

The DOI matches its Crossref record.

Multichannel optical correlator/convolver utilizing the magnetooptic spatial light modulator

Davis, Jeffrey A., Day, Timothy, Lilly, Roger A., Liu, Hua-Kuang·1987·Applied Optics

Abstract

We describe a multichannel correlator/convolver architecture utilizing an acoustooptic light modulator for the 1-D input channel and a magnetooptic spatial light modulator (MOSLM) for the second 2-D parallel channel. The MOSLM allows greater parallelism to be implemented into this correlator/convolver design than was previously reported. We demonstrate the implementation of 24 parallel channels with a 48 x 48 device. We present experimental data and discuss ways of increasing the number of parallel channels using commercially available MOSLMs and other previously discussed techniques such as frequency multiplexing. We show that over 2000 parallel channels are possible at 32-bit accuracy. A technique for obtaining a limited gray scale is also discussed.

Overview

Integrity signals

Registry

Crossref · 10.1364/ao.26.002479

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 15

  1. Cutrona, 1960, IRE Trans. Inf. Theory, IT6, 386, 10.1109/TIT.1960.1057566 · DOI
  2. Casasent, 1985, Appl. Opt., 24, 856, 10.1364/AO.24.000856 · DOI
  3. Casasent, 1985, Appl. Opt., 24, 2884, 10.1364/AO.24.002884 · DOI
  4. Cohen, 1982, Proc. Soc. Photo-Opt. Instrum. Eng., 341, 165
  5. Casasent, 1986, Appl. Opt., 25, 2256
  6. Casasent, 1986, Appl. Opt., 25, 3217, 10.1364/AO.25.003217 · DOI
  7. Ross, 1983, Opt. Eng., 22, 485, 10.1117/12.7973148 · DOI
  8. Swartzlander, 1973, IEEE Trans. Comput., C22, 317, 10.1109/T-C.1973.223717 · DOI
  9. Psaltis, 1980, Proc. Soc. Photo-Opt. Instrum. Eng., 232, 151
  10. Rhodes, 1981, Proc. IEEE, 69, 65, 10.1117/12.7973246 · DOI
  11. Guilfoyle, 1984, Opt. Eng., 23, 20, 10.1117/12.7973246 · DOI
  12. Rhodes, 1984, Proc. IEEE, 72, 820, 10.1109/PROC.1984.12941 · DOI
  13. Davis, 1986, Opt. Eng., 25, 572
  14. Psaltis, 1986, Appl. Opt., 25, 3071, 10.1364/AO.25.003071 · DOI
  15. Athale, 1986, Appl. Opt., 25, 3122, 10.1364/AO.25.003122 · DOI

Cited by

Sorted by citations

Metadata

Authors
Davis, J. A., Day, T., Lilly, R. A., & Liu, H.-K.
Venue
Applied Optics
Published
1987-06-15
Volume
26
Issue
12
Pages
2479
ISSN
  • 0003-6935
  • 1539-4522
Cited by
10
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review