Pump/probe method for fast analysis of visible spectral signatures utilizing asynchronous optical sampling
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We report the results from a new pump/probe spectrometer for potential use in combustion diagnostics that employs asynchronous optical sampling. The instrument consists of two frequency-doubled mode-locked Nd:YAG lasers operating at slightly different repetition rates, synchronously pumping two dye lasers (rhodamine 6G) to generate the pump and probe beams. The spectral and temporal capabilities of the instrument are examined by obtaining a spectrum and an excited state decay of rhodamine B. The instrument response is shown to be proportional to pump power, probe power, and sample absorptance. Different frequency synthesizers and different modes of triggering are used to study their effect on signal stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pump/Probe Spectroscopy by Asynchronous Optical Sampling
Elzinga, P. A., Lytle, F. E., Jian, Y., King, G. B., & Laurendeau, N. M. (1987) · Applied Spectroscopy · doi:10.1366/0003702874868025 · Cited by 115
Self-citation
Cited by
Ultrafast time-domain spectroscopy based on high-speed asynchronous optical sampling
Bartels, A., Cerna, R., Kistner, C., Thoma, A., Hudert, F., Janke, C., & Dekorsy, T. (2007) · Review of Scientific Instruments · doi:10.1063/1.2714048 · Cited by 460
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322
Yasui, T., Saneyoshi, E., & Araki, T. (2005) · Applied Physics Letters · doi:10.1063/1.2008379 · Cited by 265
Coherent sampling of active mode-locked terahertz quantum cascade lasers and frequency synthesis
Barbieri, S., Ravaro, M., Gellie, P., Santarelli, G., Manquest, C., Sirtori, C., Khanna, S. P., Linfield, E. H., & Davies, A. G. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.49 · Cited by 223
“Mode-locked femtosecond lasers are established sources for probing fast transient phenomena, with pump–probe experiments using two mode-locked femtosecond lasers with slightly different repetition rates becoming widesprea”
BackgroundRapid-scanning terahertz precision spectrometer with more than 6 THz spectral coverage
Klatt, G., Gebs, R., Janke, C., Dekorsy, T., & Bartels, A. (2009) · Optics Express · doi:10.1364/oe.17.022847 · Cited by 95
Metadata
- Authors
- Elzinga, P. A., Kneisler, R. J., Lytle, F. E., Jiang, Y., King, G. B., & Laurendeau, N. M.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1987-10-01
- Volume
- 26
- Issue
- 19
- Pages
- 4303
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1982324708
- Cited by
- 194
- References
- 1
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pump/probe method for fast analysis of visible spectral signatures utilizing asynchronous optical sampling. https://app.cochat.ai/papers/10.1364/ao.26.004303
- The paper
- Elzinga, P. A., Kneisler, R. J., Lytle, F. E., Jiang, Y., King, G. B., & Laurendeau, N. M. (1987). Pump/probe method for fast analysis of visible spectral signatures utilizing asynchronous optical sampling. Applied Optics. https://doi.org/10.1364/ao.26.004303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.