The DOI matches its Crossref record.
Refractive index of solutions at high concentrations
Abstract
The refractive index of liquid solutions at the He-Ne laser wavelength, 0.6328 microm, is presented. The measurements were carried out using the conventional minimum deviation method of an equilateral hollow glass prism. The refractive indices of sucrose, sodium chloride, glucose, and caster sugar solutions for a range of density varying from distilled water to a saturated condition were measured. The result shows that at higher concentrations a slight curvature can be seen from the plot of refractive index vs concentration of solution. However, the refractive index of sucrose shows a linear relationship with concentration. The accuracy of the measurements is estimated to be better than 0.3%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 4
- Grange, 1976, Appl. Opt., 15, 858, 10.1364/AO.15.000858 · doi:10.1364/ao.15.000858
- Jenkin, 1982, Phys. Educ., 17, 82, 10.1088/0031-9120/17/2/413 · doi:10.1088/0031-9120/17/2/413
- Cariou, 1986, Appl. Opt., 25, 334, 10.1364/AO.25.000334 · DOI
- Bass, 1984, Rev. Sci. Instrum., 55, 1569, 10.1063/1.1137611 · doi:10.1063/1.1137611
Cited by
Nanoparticles Engineering by Pulsed Laser Ablation in Liquids: Concepts and Applications
Fazio, E., Gökce, B., De Giacomo, A., Meneghetti, M., Compagnini, G., Tommasini, M., Waag, F., Lucotti, A., Zanchi, C. G., Ossi, P. M., et al. (2020) · Nanomaterials · doi:10.3390/nano10112317 · Cited by 346
“S can be easily measured by performing a relatively simple experiment in which a small aliquot of colloid solution is mixed with a sucrose solution at a set concentration, in a 20–70% range, where a direct relationship between sucrose concentration and refractive index exists [168].”
BackgroundMethodRefractive Index Measurement and its Applications
Singh, S. (2002) · Physica Scripta · doi:10.1238/physica.regular.065a00167 · Cited by 270
Plasmon sensing and enhancement of laser prepared silver colloidal nanoplates
Condorelli, M., Scardaci, V., D'Urso, L., Puglisi, O., Fazio, E., & Compagnini, G. (2019) · Applied Surface Science · doi:10.1016/j.apsusc.2018.12.265 · Cited by 27
Scardaci, V., Pulvirenti, M., Condorelli, M., & Compagnini, G. (2020) · Journal of Materials Chemistry C · doi:10.1039/d0tc00367k · Cited by 14
Metadata
- Authors
- Yunus, W. M. B. M., & Rahman, A. B. A.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1988-08-15
- Volume
- 27
- Issue
- 16
- Pages
- 3341
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2086052136
- Cited by
- 197
- References
- 0
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- doi.org/10.1364/OA_License_v1#VOR (vor)
- opg.optica.org/policies/opg-tdm-policy.json (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Refractive index of solutions at high concentrations. https://app.cochat.ai/papers/10.1364/ao.27.003341
- The paper
- Yunus, W. M. B. M., & Rahman, A. B. A. (1988). Refractive index of solutions at high concentrations. Applied Optics. https://doi.org/10.1364/ao.27.003341
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.