The DOI matches its Crossref record.
Refractive index of some mammalian tissues using a fiber optic cladding method
Abstract
The index of refraction n of the many mammalian tissues is an important but somewhat neglected optical constant. Archival and oral papers have quoted the use of values of n for tissue generally ranging from 1.35 to 1.55. However, these values are frequently without experimental basis. They have arbitrarily used values near that of water, which is a major component of mammalian tissue, or have calculated a theoretical n from the weighted elemental composition of tissue. Since these values have not been precise and little information is available on specific indices for each tissue, a study was undertaken to develop a simple, rapid, and reliable method for the experimental determination of n. This was done using the ubiquitous quartz optical fiber. By substituting the usual cladding found on commercial quartz optics by the tissue in question and utilizing the principle of internal reflection, the value of n for the specific tissue can be calculated. This is done by utilizing the known indices for air and quartz and measuring the angle of the emergent cone of light from the output of the optical fiber. A number of indices for mammalian tissue (bovine, porcine, canine, and human) have been determined at 632.8 nm. With few exceptions, for tissues at this wavelength, n was in the 1.38-1.41 range. The species type did not appear to be a factor. Bovine muscle showed normal dispersion characteristics through the visible wavelengths. The denaturation of tissue was shown to alter significantly the refractive index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
Kienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Optical properties of normal and diseased human breast tissues in the visible and near infrared
Peters, V. G., Wyman, D. R., Patterson, M. S., & Frank, G. L. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/9/010 · Cited by 414
Niedre, M., Patterson, M. S., & Wilson, B. C. (2002) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2002)0750382dnildo2.0.co2 · Cited by 396
Metadata
- Authors
- Bolin, F. P., Preuss, L. E., Taylor, R. C., & Ference, R. J.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1989-06-15
- Volume
- 28
- Issue
- 12
- Pages
- 2297
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2043825393
- Cited by
- 522
- References
- 0
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Refractive index of some mammalian tissues using a fiber optic cladding method. https://app.cochat.ai/papers/10.1364/ao.28.002297
- The paper
- Bolin, F. P., Preuss, L. E., Taylor, R. C., & Ference, R. J. (1989). Refractive index of some mammalian tissues using a fiber optic cladding method. Applied Optics. https://doi.org/10.1364/ao.28.002297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.