Richardson-Lucy/maximum likelihood image restoration algorithm for fluorescence microscopy: further testing
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A maximum likelihood based iterative algorithm adapted from nuclear medicine imaging for noncoherent optical imaging was presented in a previous publication with some initial computer-simulation testing. This algorithm is identical in form to that previously derived in a different way by W. H. Richardson "Bayesian-Based Iterative Method of Image Restoration," J. Opt. Soc. Am. 62, 55-59 (1972) and L. B. Lucy "An Iterative Technique for the Rectification of Observed Distributions," Astron. J. 79, 745-765 (1974). Foreseen applications include superresolution and 3-D fluorescence microscopy. This paper presents further simulation testing of this algorithm and a preliminary experiment with a defocused camera. The simulations show quantified resolution improvement as a function of iteration number, and they show qualitatively the trend in limitations on restored resolution when noise is present in the data. Also shown are results of a simulation in restoring missing-cone information for 3-D imaging. Conclusions are in support of the feasibility of using these methods with real systems, while computational cost and timing estimates indicate that it should be realistic to implement these methods. Itis suggested in the Appendix that future extensions to the maximum likelihood based derivation of this algorithm will address some of the limitations that are experienced with the nonextended form of the algorithm presented here.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866
Cited by
Conchello, J.-A., & Lichtman, J. W. (2005) · Nature Methods · doi:10.1038/nmeth815 · Cited by 798
Distinct fission signatures predict mitochondrial degradation or biogenesis.
Kleele, T., Rey, T., Winter, J., Zaganelli, S., Mahecic, D., Perreten Lambert, H., Ruberto, F. P., Nemir, M., Wai, T., Pedrazzini, T., et al. (2021) · Nature · doi:10.1038/s41586-021-03510-6 · Cited by 794
Image deblurring with Poisson data: from cells to galaxies
Bertero, M., Boccacci, P., Desiderà, G., & Vicidomini, G. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123006 · Cited by 308
Maturation-Dependent HIV-1 Surface Protein Redistribution Revealed by Fluorescence Nanoscopy
Chojnacki, J., Staudt, T., Glass, B., Bingen, P., Engelhardt, J., Anders, M., Schneider, J., Müller, B., Hell, S. W., & Kräusslich, H.-G. (2012) · Science · doi:10.1126/science.1226359 · Cited by 283
Two-Color Far-Field Fluorescence Nanoscopy
Donnert, G., Keller, J., Wurm, C. A., Rizzoli, S. O., Westphal, V., Schönle, A., Jahn, R., Jakobs, S., Eggeling, C., & Hell, S. W. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104497 · Cited by 256
Metadata
- Authors
- Holmes, T. J., & Liu, Y.-H.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1989-11-15
- Volume
- 28
- Issue
- 22
- Pages
- 4930
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1976947498
- Cited by
- 53
- References
- 3
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Richardson-Lucy/maximum likelihood image restoration algorithm for fluorescence microscopy: further testing. https://app.cochat.ai/papers/10.1364/ao.28.004930
- The paper
- Holmes, T. J., & Liu, Y.-H. (1989). Richardson-Lucy/maximum likelihood image restoration algorithm for fluorescence microscopy: further testing. Applied Optics. https://doi.org/10.1364/ao.28.004930
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.