The DOI matches its Crossref record.
Spatially resolved birefringence of the retinal nerve fiber layer assessed with a retinal laser ellipsometer
Abstract
A retinal laser ellipsometer has been developed by coupling a Fourier ellipsometer to a laser scanning system. The instrument has been used to assess the origin and the amount of change in the state of polarization of a laser beam that has double passed the retina around the optic nerve head of postmortemhuman eyes. Eight eyes with no history of glaucoma were studied. At 200 points around the optic nerve head of each eye the Mueller matrices of the retina were examined for the amount of retardation, the orientation of the optic axis, and the amount of dichroism. The degree of polarization preservation of the detected light varied between 50% and 87%. Little dichroism was found, and there was no obvious correlation to the physical arrangement of any retinal structure. However, there was a substantial amount of linear uniaxial birefringence with the optic axis perpendicular to the incident laser beam. Furthermore the calculated optic axis direction showed a strong correlation with the physical orientation of the radial symmetrically arranged retinal nerve fiber axons around the optic nerve head. The local distribution of the corresponding retardation values showed two maxima that coincided with the areas of the thickest retinal nerve fiber layer. These results support the hypothesis that the thickness of the form birefringent retinal nerve fiber layer can be assessed by ellipsometric methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence Tomography
Wojtkowski, M., Srinivasan, V., Fujimoto, J. G., Ko, T., Schuman, J. S., Kowalczyk, A., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.023 · Cited by 640
Polarization sensitive optical coherence tomography – a review [Invited]
de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001838 · Cited by 454
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
Polarization sensitive optical coherence tomography in the human eye
Pircher, M., Hitzenberger, C. K., & Schmidt-Erfurth, U. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.06.003 · Cited by 288
Metadata
- Authors
- Dreher, A. W., Reiter, K., & Weinreb, R. N.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1992-07-01
- Volume
- 31
- Issue
- 19
- Pages
- 3730
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2059699833
- Cited by
- 217
- References
- 0
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatially resolved birefringence of the retinal nerve fiber layer assessed with a retinal laser ellipsometer. https://app.cochat.ai/papers/10.1364/ao.31.003730
- The paper
- Dreher, A. W., Reiter, K., & Weinreb, R. N. (1992). Spatially resolved birefringence of the retinal nerve fiber layer assessed with a retinal laser ellipsometer. Applied Optics. https://doi.org/10.1364/ao.31.003730
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.