The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Optical coherence tomography - principles and applications
Open accessAbstract
There have been three basic approaches to optical tomography since the early 1980s: diffraction tomography, diffuse optical tomography and optical coherence tomography (OCT). Optical techniques are of particular importance in the medical field, because these techniques promise to be safe and cheap and, in addition, offer a therapeutic potential. Advances in OCT technology have made it possible to apply OCT in a wide variety of applications but medical applications are still dominating. Specific advantages of OCT are its high depth and transversal resolution, the fact, that its depth resolution is decoupled from transverse resolution, high probing depth in scattering media, contact-free and non-invasive operation, and the possibility to create various function dependent image contrasting methods. This report presents the principles of OCT and the state of important OCT applications. OCT synthesises cross-sectional images from a series of laterally adjacent depth-scans. At present OCT is used in three different fields of optical imaging, in macroscopic imaging of structures which can be seen by the naked eye or using weak magnifications, in microscopic imaging using magnifications up to the classical limit of microscopic resolution and in endoscopic imaging, using low and medium magnification. First, OCT techniques, like the reflectometry technique and the dual beam technique were based on time-domain low coherence interferometry depth-scans. Later, Fourier-domain techniques have been developed and led to new imaging schemes. Recently developed parallel OCT schemes eliminate the need for lateral scanning and, therefore, dramatically increase the imaging rate. These schemes use CCD cameras and CMOS detector arrays as photodetectors. Video-rate three-dimensional OCT pictures have been obtained. Modifying interference microscopy techniques has led to high-resolution optical coherence microscopy that achieved sub-micrometre resolution. This report is concluded with a short presentation of important OCT applications. Ophthalmology is, due to the transparent ocular structures, still the main field of OCT application. The first commercial instrument too has been introduced for ophthalmic diagnostics (Carl Zeiss Meditec AG). Advances in using near-infrared light, however, opened the path for OCT imaging in strongly scattering tissues. Today, optical in vivo biopsy is one of the most challenging fields of OCT application. High resolution, high penetration depth, and its potential for functional imaging attribute to OCT an optical biopsy quality, which can be used to assess tissue and cell function and morphology in situ . OCT can already clarify the relevant architectural tissue morphology. For many diseases, however, including cancer in its early stages, higher resolution is necessary. New broad-bandwidth light sources, like photonic crystal fibres and superfluorescent fibre sources, and new contrasting techniques, give access to new sample properties and unmatched sensitivity and resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Coherence and Quantum Optics
Mandel, L., & Wolf, E. (1995) · doi:10.1017/cbo9781139644105 · Cited by 8,356
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citation
Cited by
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Spectral-domain phase microscopy
Choma, M. A., Ellerbee, A. K., Yang, C., Creazzo, T. L., & Izatt, J. A. (2005) · Optics Letters · doi:10.1364/ol.30.001162 · Cited by 342
Aqueous outflow - A continuum from trabecular meshwork to episcleral veins
Carreon, T., van der Merwe, E., Fellman, R. L., Johnstone, M., & Bhattacharya, S. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.004 · Cited by 312
Baumann, B., Baumann, S. O., Konegger, T., Pircher, M., Götzinger, E., Schlanitz, F., Schütze, C., Sattmann, H., Litschauer, M., Schmidt-Erfurth, U., et al. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001670 · Cited by 163
Self-citationQuantum optical coherence tomography of a biological sample
Nasr, M. B., Goode, D. P., Nguyen, N., Rong, G., Yang, L., Reinhard, B. M., Saleh, B. E. A., & Teich, M. C. (2009) · Optics Communications · doi:10.1016/j.optcom.2008.11.061 · Cited by 79
Metadata
- Authors
- Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2003-01-20
- Volume
- 66
- Issue
- 2
- Pages
- 239-303
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2078920062
- Cited by
- 1,866
- References
- 3
- FWCI
- 39.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical coherence tomography - principles and applications. https://app.cochat.ai/papers/10.1088/0034-4885/66/2/204
- The paper
- Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003). Optical coherence tomography - principles and applications. Reports on Progress in Physics. https://doi.org/10.1088/0034-4885/66/2/204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.