The DOI matches its Crossref record.
Spectral dependence of temporal point spread functions in human tissues
Abstract
We have determined the spectral dependence of the temporal point spread functions of human tissues experimentally between 740 and 840 nm in transmittance measurements on the adult head, forearm, and calf (in vivo) and the infant head (post mortem) by using picosecond laser pulses and a streak camera detector. Two parameters are extracted from the temporal point spread function; the differential path-length factor (DPF), calculated from the mean time, and the slope of the logarithmic intensity decay. In all tissues the DPF and the logarithmic slope show a reciprocal relationship and exhibit characteristics of the absorption spectra of hemoglobin. The DPF falls with increasing wavelength, the variation being typically 12%, while the logarithmic slope increases with wavelength. A quantitative analysis of the logarithmic slope spectrum significantly underestimated expected tissue chromophore concentrations. The absolute magnitudes of the DPF showed considerable intersubject variation, but the variation with wavelength was consistent and thus may be used in the correction of tissue attenuation spectra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Self-citationStrangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Self-citationHerold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Metadata
- Authors
- Essenpreis, M., Elwell, C. E., Cope, M., van der Zee, P., Arridge, S. R., & Delpy, D. T.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1993-02-01
- Volume
- 32
- Issue
- 4
- Pages
- 418
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2075306607
- Cited by
- 195
- References
- 0
- FWCI
- 8.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectral dependence of temporal point spread functions in human tissues. https://app.cochat.ai/papers/10.1364/ao.32.000418
- The paper
- Essenpreis, M., Elwell, C. E., Cope, M., van der Zee, P., Arridge, S. R., & Delpy, D. T. (1993). Spectral dependence of temporal point spread functions in human tissues. Applied Optics. https://doi.org/10.1364/ao.32.000418
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.