The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Limited-data computed tomography algorithms for the physical sciences
Abstract
Five limited-data computed tomography algorithms are compared. The algorithms used are adapted versions of the algebraic reconstruction technique, the multiplicative algebraic reconstruction technique, the Gerchberg-Papoulis algorithm, a spectral extrapolation algorithm descended from that of Harris [J. Opt. Soc. Am. 54, 931-936 (1964)], and an algorithm based on the singular value decomposition technique. These algorithms were used to reconstruct phantom data with realistic levels of noise from a number of different imaging geometries. The phantoms, the imaging geometries, and the noise were chosen to simulate the conditions encountered in typical computed tomography applications in the physical sciences, and the implementations of the algorithms were optimized for these applications. The multiplicative algebraic reconstruction technique algorithm gave the best results overall; the algebraic reconstruction technique gave the best results for very smooth objects or very noisy (20-dB signal-to-noise ratio) data. My implementations of both of these algorithms incorporate apriori knowledge of the sign of the object, its extent, and its smoothness. The smoothness of the reconstruction is enforced through the use of an appropriate object model (by use of cubic B-spline basis functions and a number of object coefficients appropriate to the object being reconstructed). The average reconstruction error was 1.7% of the maximum phantom value with the multiplicative algebraic reconstruction technique of a phantom with moderate-to-steep gradients by use of data from five viewing angles with a 30-dB signal-to-noise ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
Tomographic particle image velocimetry
Elsinga, G. E., Scarano, F., Wieneke, B., & van Oudheusden, B. W. (2006) · Experiments in Fluids · doi:10.1007/s00348-006-0212-z · Cited by 1,251
Riethmuller, M., David, L., & Lecordier, B. (2012) · Laser Velocimetry in Fluid Mechanics · doi:10.1002/9781118569610.ch6 · Cited by 516
Delaney, A. H., & Bresler, Y. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.660997 · Cited by 304
Evaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography
Boas, F. E., & Fleischmann, D. (2011) · Radiology · doi:10.1148/radiol.11101782 · Cited by 303
Metadata
- Authors
- Verhoeven, D.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1993-07-10
- Volume
- 32
- Issue
- 20
- Pages
- 3736
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2000274929
- Cited by
- 202
- References
- 1
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limited-data computed tomography algorithms for the physical sciences. https://app.cochat.ai/papers/10.1364/ao.32.003736
- The paper
- Verhoeven, D. (1993). Limited-data computed tomography algorithms for the physical sciences. Applied Optics. https://doi.org/10.1364/ao.32.003736
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.