CoChat

Comparison of Sun photometer calibration by use of the Langley technique and the standard lamp

Schmid, Beat, Wehrli, Christoph · 1995 · Applied Optics
Cited by 167

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Asix-channel Sun photometer has been calibrated by means of two different methods: Langley plots and standard irradiance lamps. A 4-month calibration campaign was carried out at a high mountain site, Jungfraujoch (3580 m above sea level), in the Swiss Alps. Calibration constants V(0)(λ) determined on clear and stable days by means of a refined Langley-plot technique scatter by less than 0.25% (rms) for wavelengths outside of strong gaseous absorption bands. Inside the 0.94-µm water-vapor absorption band, the V(0)(λ) values retrieved by means of modified Langley plots scatter by 1.0% (rms). Repeated calibrations of the Sun photometer by means of irradiance standard lamps were performed at the World Radiation Center in Davos. The comparison of both methods ranges from perfect agreement to a deviation of 4.9% for the different channels. A discussion of the errors introduced by both methods shows that the Langley-plot calibration, when performed under very clear atmospheric conditions, is superior. However, by means of the standard-lamp calibrations a temporal degradation of the instrument's response up to 4.6% per year was found, implying that a single calibration campaign as done here is not sufficient. Thus we recommend the use of a combination of both methods for maintaining an accurate calibration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.34.004500

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 167

Metadata

Authors
Schmid, B., & Wehrli, C.
Venue
Applied Optics
Published
1995-07-20
Volume
34
Issue
21
Pages
4500
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2124416218
Cited by
167
References
10
FWCI
8.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.