The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Avalanche photodiodes and quenching circuits for single-photon detection
Abstract
Avalanche photodiodes, which operate above the breakdown voltage in Geiger mode connected with avalanche-quenching circuits, can be used to detect single photons and are therefore called singlephoton avalanche diodes SPAD's. Circuit configurations suitable for this operation mode are critically analyzed and their relative merits in photon counting and timing applications are assessed. Simple passive-quenching circuits (PQC's), which are useful for SPAD device testing and selection, have fairly limited application. Suitably designed active-quenching circuits (AQC's) make it possible to exploit the best performance of SPAD's. Thick silicon SPAD's that operate at high voltages (250-450 V) have photon detection efficiency higher than 50% from 540- to 850-nm wavelength and still ~3% at 1064 nm. Thin silicon SPAD's that operate at low voltages (10-50 V) have 45% efficiency at 500 nm, declining to 10% at 830 nm and to as little as 0.1% at 1064 nm. The time resolution achieved in photon timing is 20 ps FWHM with thin SPAD's; it ranges from 350 to 150 ps FWHM with thick SPAD's. The achieved minimum counting dead time and maximum counting rate are 40 ns and 10 Mcps with thick silicon SPAD's, 10 ns and 40 Mcps with thin SPAD's. Germanium and III-V compound semiconductor SPAD's extend the range of photon-counting techniques in the near-infrared region to at least 1600-nm wavelength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental violation of Bell’s inequality based on phase and momentum
Rarity, J. G., & Tapster, P. R. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.2495 · Cited by 612
Cited by
Gisin, N., Ribordy, G., Tittel, W., & Zbinden, H. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.145 · Cited by 8,515
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Quantum Cryptography with Entangled Photons
Jennewein, T., Simon, C., Weihs, G., Weinfurter, H., & Zeilinger, A. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.4729 · Cited by 940
Waveguide-integrated superconducting nanowire single-photon detectors
Ferrari, S., Schuck, C., & Pernice, W. (2017) · Nanophotonics · doi:10.1515/nanoph-2018-0059 · Cited by 167
Imaging and certifying high-dimensional entanglement with a single-photon avalanche diode camera
Ndagano, B., Defienne, H., Lyons, A., Starshynov, I., Villa, F., Tisa, S., & Faccio, D. (2020) · npj Quantum Information · doi:10.1038/s41534-020-00324-8 · Cited by 76
Metadata
- Authors
- Cova, S., Ghioni, M., Lacaita, A., Samori, C., & Zappa, F.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1996-04-20
- Volume
- 35
- Issue
- 12
- Pages
- 1956
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1975496472
- Cited by
- 1,114
- References
- 1
- FWCI
- 32.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Avalanche photodiodes and quenching circuits for single-photon detection. https://app.cochat.ai/papers/10.1364/ao.35.001956
- The paper
- Cova, S., Ghioni, M., Lacaita, A., Samori, C., & Zappa, F. (1996). Avalanche photodiodes and quenching circuits for single-photon detection. Applied Optics. https://doi.org/10.1364/ao.35.001956
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.