The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Avalanche photodiodes and quenching circuits for single-photon detection
Abstract
Avalanche photodiodes, which operate above the breakdown voltage in Geiger mode connected with avalanche-quenching circuits, can be used to detect single photons and are therefore called singlephoton avalanche diodes SPAD's. Circuit configurations suitable for this operation mode are critically analyzed and their relative merits in photon counting and timing applications are assessed. Simple passive-quenching circuits (PQC's), which are useful for SPAD device testing and selection, have fairly limited application. Suitably designed active-quenching circuits (AQC's) make it possible to exploit the best performance of SPAD's. Thick silicon SPAD's that operate at high voltages (250-450 V) have photon detection efficiency higher than 50% from 540- to 850-nm wavelength and still ~3% at 1064 nm. Thin silicon SPAD's that operate at low voltages (10-50 V) have 45% efficiency at 500 nm, declining to 10% at 830 nm and to as little as 0.1% at 1064 nm. The time resolution achieved in photon timing is 20 ps FWHM with thin SPAD's; it ranges from 350 to 150 ps FWHM with thick SPAD's. The achieved minimum counting dead time and maximum counting rate are 40 ns and 10 Mcps with thick silicon SPAD's, 10 ns and 40 Mcps with thin SPAD's. Germanium and III-V compound semiconductor SPAD's extend the range of photon-counting techniques in the near-infrared region to at least 1600-nm wavelength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shih, Y. H., & Alley, C. O. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.2921 · Cited by 917
Experimental violation of Bell’s inequality based on phase and momentum
Rarity, J. G., & Tapster, P. R. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.2495 · Cited by 612
Photon counting techniques with silicon avalanche photodiodes
Dautet, H., Deschamps, P., Dion, B., MacGregor, A. D., MacSween, D., McIntyre, R. J., Trottier, C., & Webb, P. P. (1993) · Applied Optics · doi:10.1364/ao.32.003894 · Cited by 284
Single photon interference in 10 km long optical fibre interferometer
Townsend, P. D., Rarity, J. G., & Tapster, P. R. (1993) · Electronics Letters · doi:10.1049/el:19930424 · Cited by 282
Towards picosecond resolution with single-photon avalanche diodes
Cova, S., Longoni, A., & Andreoni, A. (1981) · Review of Scientific Instruments · doi:10.1063/1.1136594 · Cited by 219
Self-citationMechanisms Contributing to the Noise Pulse Rate of Avalanche Diodes
Haitz, R. H. (1965) · Journal of Applied Physics · doi:10.1063/1.1702936 · Cited by 200
Model for the Electrical Behavior of a Microplasma
Haitz, R. H. (1964) · Journal of Applied Physics · doi:10.1063/1.1713636 · Cited by 193
Brown, R. G. W., Ridley, K. D., & Rarity, J. G. (1986) · Applied Optics · doi:10.1364/ao.25.004122 · Cited by 185
Single-photon detection beyond 1 μm: performance of commercially available InGaAs/InP detectors
Lacaita, A., Zappa, F., Cova, S., & Lovati, P. (1996) · Applied Optics · doi:10.1364/ao.35.002986 · Cited by 167
Self-citationPhoton burst detection of single near-infrared fluorescent molecules
Soper, S. A., Mattingly, Q. L., & Vegunta, P. (1993) · Analytical Chemistry · doi:10.1021/ac00054a015 · Cited by 145
Single photon avalanche diode for single molecule detection
Li, L., & Davis, L. M. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144463 · Cited by 143
20-ps timing resolution with single-photon avalanche diodes
Cova, S., Lacaita, A. L., Ghioni, M., Ripamonti, G., & Louis, T. A. (1989) · Review of Scientific Instruments · doi:10.1063/1.1140324 · Cited by 136
Self-citationBrown, R. G. W., Jones, R., Rarity, J., & Ridley, K. D. (1987) · Applied Optics · doi:10.1364/ao.26.002383 · Cited by 127
Ultrafast microchannel plate photomultipliers
Kume, H., Koyama, K., Nakatsugawa, K., Suzuki, S., & Fatlowitz, D. (1988) · Applied Optics · doi:10.1364/ao.27.001170 · Cited by 120
Single-photon detection beyond 1 μm: performance of commercially available germanium photodiodes
Lacaita, A. L., Francese, P. A., Zappa, F., & Cova, S. (1994) · Applied Optics · doi:10.1364/ao.33.006902 · Cited by 87
Self-citationActive-Quenching and Gating Circuits for Single-Photon Avalanche Diodes (SPADs)
Cova, S., Longoni, A. F., & Ripamonti, G. (1982) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1982.4335917 · Cited by 81
Self-citationFluorescence lifetime measurements using a novel fiber-optic laser scanning confocal microscope
Ghiggino, K. P., Harris, M., & Spizzirri, P. G. (1992) · Review of Scientific Instruments · doi:10.1063/1.1142599 · Cited by 80
Single-photon optical-time-domain reflectometer at 13 μm with 5-cm resolution and high sensitivity
Lacaita, A. L., Riparmonti, G., Francese, P. A., & Cova, S. (1993) · Optics Letters · doi:10.1364/ol.18.001110 · Cited by 63
Self-citationLevine, B. F., Bethea, C. G., & Campbell, J. C. (1985) · Applied Physics Letters · doi:10.1063/1.95622 · Cited by 60
Single photon detection at 1.3 μm using a gated avalanche photodiode
Levine, B. F., & Bethea, C. G. (1984) · Applied Physics Letters · doi:10.1063/1.94800 · Cited by 58
Photon counting with photodiodes
Ingerson, T. E., Kearney, R. J., & Coulter, R. L. (1983) · Applied Optics · doi:10.1364/ao.22.002013 · Cited by 41
Buller, G. S., Massa, J. S., & Walker, A. C. (1992) · Review of Scientific Instruments · doi:10.1063/1.1142598 · Cited by 29
Strong dependence of time resolution on detector diameter in single photon avalanche diodes
Lacaita, A. L., & Mastrapasqua, M. (1990) · Electronics Letters · doi:10.1049/el:19901324 · Cited by 26
Self-citationNanosecond single-photon timing with InGaAs/InP photodiodes
Zappa, F., Webb, P., Lacaita, A. L., & Cova, S. (1994) · Optics Letters · doi:10.1364/ol.19.000846 · Cited by 26
Self-citationOptical time-domain reflectometry with centimetre resolution at 10 −15 W sensitivity
Ripamonti, G., & Cova, S. (1986) · Electronics Letters · doi:10.1049/el:19860561 · Cited by 18
Self-citationAvalanche transients in shallow p-n junctions biased above breakdown
Lacaita, A. L., Spinelli, A. S., & Longhi, S. (1995) · Applied Physics Letters · doi:10.1063/1.114317 · Cited by 12
Self-citationHigh-accuracy picosecond characterization of gain-switched laser diodes
Cova, S., Lacaita, A. L., Ghioni, M., & Ripamonti, G. (1989) · Optics Letters · doi:10.1364/ol.14.001341 · Cited by 12
Self-citation
Cited by
Gisin, N., Ribordy, G., Tittel, W., & Zbinden, H. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.145 · Cited by 8,515
Nanostructured materials for photon detection
Konstantatos, G., & Sargent, E. H. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.78 · Cited by 1,463
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Quantum Cryptography with Entangled Photons
Jennewein, T., Simon, C., Weihs, G., Weinfurter, H., & Zeilinger, A. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.4729 · Cited by 940
Protein Conformational Dynamics Probed by Single-Molecule Electron Transfer
Yang, H., Luo, G., Karnchanaphanurach, P., Louie, T.-M., Rech, I., Cova, S., Xun, L., & Xie, X. S. (2003) · Science · doi:10.1126/science.1086911 · Cited by 843
Self-citation
Metadata
- Authors
- Cova, S., Ghioni, M., Lacaita, A., Samori, C., & Zappa, F.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1996-04-20
- Volume
- 35
- Issue
- 12
- Pages
- 1956
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1975496472
- Cited by
- 1,114
- References
- 27
- FWCI
- 32.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.