Inverse hybrid technique for determining the optical properties of turbid media from integrating-sphere measurements
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We have combined the Monte Carlo method with the small-angle approximation of the radiative transfer theory to derive the optical properties (the absorption coefficient, the scattering coefficient, and the anisotropy factor) of turbid materials from integrating-sphere measurements (the total transmittance and the diffuse reflectance) and the collimated transmittance. Unlike one-dimensional models, the technique accounts for the side losses of light at the edges of the sample. In addition, it enables the correction of the measured collimated signal for the contribution of multiply scattered light. On the other hand, the hybrid technique allows a significant reduction in calculation time compared with inverse methods based on a pure Monte Carlo technique. Numerical tests and experimental results from a phantom material (milk) as well as samples of biological tissue (porcine myocardium) confirmed the feasibility of applying this technique to the determination of the optical properties of turbid media.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
“The inverse Monte Carlo technique [67] can also be used for the arbitrary ratio of µ a and µ s , but requires very extensive calculations.”
MethodOPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Yaroslavsky, A. N., Schulze, P. C., Yaroslavsky, I. V., Schober, R., Ulrich, F., & Schwarzmaier, H.-J. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/305 · Cited by 651
Self-citationSalomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
Self-citationChemical nature of nitric oxide storage forms in rat vascular tissue
Rodriguez, J., Maloney, R. E., Rassaf, T., Bryan, N. S., & Feelisch, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0234600100 · Cited by 210
Metadata
- Authors
- Yaroslavsky, I. V., Yaroslavsky, A. N., Goldbach, T., & Schwarzmaier, H.-J.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1996-12-01
- Volume
- 35
- Issue
- 34
- Pages
- 6797
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2062582199
- Cited by
- 83
- References
- 1
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.