Anisotropy in the absorption and scattering spectra of chicken breast tissue
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Oblique incidence reflectometry is a simple and accurate method for measuring the absorption and the reduced-scattering coefficients of turbid media. We used this technique to deduce absorption and reduced-scattering spectra from wavelength-resolved measurements of the relative diffuse reflectance profile of white light as a function of source-detector distance. In this study, we measured the absorption and the reduced-scattering coefficients of chicken breast tissue in the visible range (400-800 nm) with the oblique incidence probe oriented at 0 degrees and 90 degrees relative to the muscle fibers. We found that the deduced optical properties varied with the probe orientation. Measurements on homogenized chicken breast tissue yielded an absorption spectrum comparable with the average of the absorption spectra for 0 degrees and 90 degrees probe orientations measured on the unhomogenized tissue. The reduced-scattering spectrum for homogeneous tissue was greater than that acquired for unhomogenized tissue taken at either probe orientation. This experiment demonstrated the application of oblique-incidence, fiber-optic reflectometry to measurements on biological tissues and the effect of tissue structural anisotropy on optical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Cited by
Dong, N.-N., Pedroni, M., Piccinelli, F., Conti, G., Sbarbati, A., Ramírez-Hernández, J. E., Maestro, L. M., Iglesias-de la Cruz, M. C., Sanz-Rodriguez, F., Juarranz, A., et al. (2011) · ACS Nano · doi:10.1021/nn202490m · Cited by 427
Subtissue Thermal Sensing Based on Neodymium-Doped LaF3Nanoparticles
Rocha, U., Jacinto da Silva, C., Ferreira Silva, W., Guedes, I., Benayas, A., Martínez Maestro, L., Acosta Elias, M., Bovero, E., van Veggel, F. C. J. M., García Solé, J. A., et al. (2013) · ACS Nano · doi:10.1021/nn304373q · Cited by 382
Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system
Kim, C., Erpelding, T. N., Jankovic, L., Pashley, M. D., & Wang, L. V. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000278 · Cited by 289
Self-citationMeat quality assessment using biophysical methods related to meat structure
Damez, J.-L., & Clerjon, S. (2008) · Meat Science · doi:10.1016/j.meatsci.2008.05.039 · Cited by 280
Propagation of polarized light in birefringent turbid media: A Monte Carlo study
Wang, X., & Wang, L. V. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483315 · Cited by 270
Self-citation
Metadata
- Authors
- Marquez, G., Wang, L. V., Lin, S.-P., Schwartz, J. A., & Thomsen, S. L.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1998-02-01
- Volume
- 37
- Issue
- 4
- Pages
- 798
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2156518535
- Cited by
- 215
- References
- 1
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.