Measurement of optical transport properties of normal and malignant human breast tissue

Ghosh, N., Mohanty, S. K., Majumder, S. K., Gupta, P. K.·2001·Applied Optics

Abstract

We report measurement of optical transport parameters of normal and malignant (ductal carcinoma) human breast tissue. A spatially resolved steady-state diffuse reflectance technique was used for measurement of the reduced scattering coefficient (mu(s)?) and the absorption coefficient (mu(a)) of the tissue. The anisotropy parameter of scattering (g) was estimated by goniophotometric measurements of the scattering phase function. The values of mu(s)? and mu(a) for malignant breast tissue were observed to be larger than those for normal breast tissue over the wavelength region investigated (450-650 nm). Further, by using both the diffuse reflectance and the goniophotometric measurements, we estimated the Mie equivalent average radius of tissue scatterers to be larger in malignant tissue than in normal tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.40.000176

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Ghosh, N., Mohanty, S. K., Majumder, S. K., & Gupta, P. K.
Venue
Applied Optics
Published
2001-01-01
Volume
40
Issue
1
Pages
176
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2167445233
Cited by
158
References
0
FWCI
6.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of optical transport properties of normal and malignant human breast tissue. https://app.cochat.ai/papers/10.1364/ao.40.000176
The paper
Ghosh, N., Mohanty, S. K., Majumder, S. K., & Gupta, P. K. (2001). Measurement of optical transport properties of normal and malignant human breast tissue. Applied Optics. https://doi.org/10.1364/ao.40.000176

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.