The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Multiwavelength three-dimensional near-infrared tomography of the breast: initial simulation, phantom, and clinical results
Abstract
Three-dimensional (3D), multiwavelength near-infrared tomography has the potential to provide new physiological information about biological tissue function and pathological transformation. Fast and reliable measurements of multiwavelength data from multiple planes over a region of interest, together with adequate model-based nonlinear image reconstruction, form the major components of successful estimation of internal optical properties of the region. These images can then be used to examine the concentration of chromophores such as hemoglobin, deoxyhemoglobin, water, and lipids that in turn can serve to identify and characterize abnormalities located deep within the domain. We introduce and discuss a 3D modeling method and image reconstruction algorithm that is currently in place. Reconstructed images of optical properties are presented from simulated data, measured phantoms, and clinical data acquired from a breast cancer patient. It is shown that, with a relatively fast 3D inversion algorithm, useful images of optical absorption and scatter can be calculated with good separation and localization in all cases. It is also shown that, by use of the calculated optical absorption over a range of wavelengths, the oxygen saturation distribution of a tissue under investigation can be deduced from oxygenated and deoxygenated hemoglobin maps. With this method the reconstructed tumor from the breast cancer patient was found to have a higher oxy-deoxy hemoglobin concentration and also a higher oxygen saturation level than the background, indicating a ductal carcinoma that corresponds well to histology findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Wray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Imaging the body with diffuse optical tomography
Boas, D. A., Brooks, D. H., Miller, E. L., DiMarzio, C. A., Kilmer, M., Gaudette, R. J., & Zhang, Q. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962278 · Cited by 718
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Photon-measurement density functions Part 2: Finite-element-method calculations
Arridge, S. R., & Schweiger, M. (1995) · Applied Optics · doi:10.1364/ao.34.008026 · Cited by 310
Optical image reconstruction using frequency-domain data: simulations and experiments
Jiang, H., Pogue, B. W., Patterson, M. S., Paulsen, K. D., & Osterberg, U. L. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.000253 · Cited by 260
Self-citationClinical optical tomography and NIR spectroscopy for breast cancer detection
Colak, S. B., van der Mark, M. B., t Hooft, G. W., Hoogenraad, J. H., van der Linden, E. S., & Kuijpers, F. A. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796341 · Cited by 248
Multichannel time-resolved optical tomographic imaging system
Eda, H., Oda, I., Ito, Y., Wada, Y., Oikawa, Y., Tsunazawa, Y., Takada, M., Tsuchiya, Y., Yamashita, Y., Oda, M., et al. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149965 · Cited by 170
Time resolved optical tomography of the human forearm
Hillman, E. M. C., Hebden, J. C., Schweiger, M. J., Dehghani, H., Schmidt, F. E. W., Delpy, D. T., & Arridge, S. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/315 · Cited by 149
Self-citation
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Self-citationRetinotopic mapping of adult human visual cortex with high-density diffuse optical tomography
Zeff, B. W., White, B. R., Dehghani, H., Schlaggar, B. L., & Culver, J. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611266104 · Cited by 351
Self-citation
Metadata
- Authors
- Dehghani, H., Pogue, B. W., Poplack, S. P., & Paulsen, K. D.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2003-01-01
- Volume
- 42
- Issue
- 1
- Pages
- 135
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1997227198
- Cited by
- 274
- References
- 16
- FWCI
- 20.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiwavelength three-dimensional near-infrared tomography of the breast: initial simulation, phantom, and clinical results. https://app.cochat.ai/papers/10.1364/ao.42.000135
- The paper
- Dehghani, H., Pogue, B. W., Poplack, S. P., & Paulsen, K. D. (2003). Multiwavelength three-dimensional near-infrared tomography of the breast: initial simulation, phantom, and clinical results. Applied Optics. https://doi.org/10.1364/ao.42.000135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.