The DOI matches its Crossref record.
A finite element approach for modeling photon transport in tissue
Abstract
The use of optical radiation in medical physics is important in several fields for both treatment and diagnosis. In all cases an analytic and computable model of the propagation of radiation in tissue is essential for a meaningful interpretation of the procedures. A finite element method (FEM) for deriving photon density inside an object, and photon flux at its boundary, assuming that the photon transport model is the diffusion approximation to the radiative transfer equation, is introduced herein. Results from the model for a particular case are given: the calculation of the boundary flux as a function of time resulting from a δ‐function input to a two‐dimensional circle (equivalent to a line source in an infinite cylinder) with homogeneous scattering and absorption properties. This models the temporal point spread function of interest in near infrared spectroscopy and imaging. The convergence of the FEM results are demonstrated, as the resolution of the mesh is increased, to the analytical expression for the Green's function for this system. The diffusion approximation is very commonly adopted as appropriate for cases which are scattering dominated, i.e., where μs≫μa, and results from other workers have compared it to alternative models. In this article a high degree of agreement with a Monte Carlo method is demonstrated. The principle advantage of the FE method is its speed. It is in all ways as flexible as Monte Carlo methods and in addition can produce photon density everywhere, as well as flux on the boundary. One disadvantage is that there is no means of deriving individual photon histories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Self-citationBoas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Quantitative spectroscopic photoacoustic imaging: a review
Cox, B., Laufer, J. G., Arridge, S. R., & Beard, P. C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061202 · Cited by 720
Self-citationSimpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Broadband (550–1350 nm) diffuse optical characterization of thyroid chromophores
Konugolu Venkata Sekar, S., Farina, A., Dalla Mora, A., Lindner, C., Pagliazzi, M., Mora, M., Aranda, G., Dehghani, H., Durduran, T., Taroni, P., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-27684-8 · Cited by 549
Metadata
- Authors
- Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1993-03
- Volume
- 20
- Issue
- 2
- Pages
- 299-309
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2151904753
- Cited by
- 635
- References
- 0
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A finite element approach for modeling photon transport in tissue. https://app.cochat.ai/papers/10.1118/1.597069
- The paper
- Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993). A finite element approach for modeling photon transport in tissue. Medical Physics. https://doi.org/10.1118/1.597069
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.