The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Terahertz imaging system based on a backward-wave oscillator
Abstract
We present an imaging system designed for use in the terahertz range. As the radiation source a backward-wave oscillator was chosen for its special features such as high output power, good wave-front quality, good stability, and wavelength tunability from 520 to 710 GHz. Detection is achieved with a pyroelectric sensor operated at room temperature. The alignment procedure for the optical elements is described, and several methods to reduce the etalon effect that are inherent in monochromatic sources are discussed. The terahertz spot size in the sample plane is 550 microm (nearly the diffraction limit), and the signal-to-noise ratio is 10,000:1; other characteristics were also measured and are presented in detail. A number of preliminary applications are also shown that cover various areas: nondestructive real-time testing for plastic tubes and packaging seals; biological terahertz imaging of fresh, frozen, or freeze-dried samples; paraffin-embedded specimens of cancer tissue; and measurement of the absorption coefficient of water by use of a wedge-shaped cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Component spatial pattern analysis of chemicals using terahertz spectroscopic imaging
Watanabe, Y., Kawase, K., Ikari, T., Ito, H., Ishikawa, Y., & Minamide, H. (2003) · Applied Physics Letters · doi:10.1063/1.1595132 · Cited by 140
Self-citation
Cited by
Vacuum Electronic High Power Terahertz Sources
Booske, J. H., Dobbs, R. J., Joye, C. D., Kory, C. L., Neil, G. R., Park, G.-S., Park, J., & Temkin, R. J. (2011) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2011.2151610 · Cited by 1,086
Imaging with terahertz radiation
Chan, W. L., Deibel, J., & Mittleman, D. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/8/r02 · Cited by 965
Terahertz Spectroscopy and Imaging for Defense and Security Applications
Liu, H.-B., Zhong, H., Karpowicz, N., Chen, Y., & Zhang, X.-C. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.898903 · Cited by 636
Tunable, continuous-wave Terahertz photomixer sources and applications
Preu, S., Döhler, G. H., Malzer, S., Wang, L. J., & Gossard, A. C. (2011) · Journal of Applied Physics · doi:10.1063/1.3552291 · Cited by 486
Lewis, R. A. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/37/374001 · Cited by 470
Metadata
- Authors
- Dobroiu, A., Yamashita, M., Ohshima, Y. N., Morita, Y., Otani, C., & Kawase, K.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2004-10-20
- Volume
- 43
- Issue
- 30
- Pages
- 5637
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2034220432
- Cited by
- 241
- References
- 1
- FWCI
- 10.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Terahertz imaging system based on a backward-wave oscillator. https://app.cochat.ai/papers/10.1364/ao.43.005637
- The paper
- Dobroiu, A., Yamashita, M., Ohshima, Y. N., Morita, Y., Otani, C., & Kawase, K. (2004). Terahertz imaging system based on a backward-wave oscillator. Applied Optics. https://doi.org/10.1364/ao.43.005637
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.